Suppr超能文献

采用α-苯偶姻肟修饰的 Amberlite XAD-2000 树脂预富集,然后运用偏最小二乘法对痕量铀、钍和锆进行同时分光光度测定。

Simultaneous spectrophotometric determination of trace amounts of uranium, thorium, and zirconium using the partial least squares method after their preconcentration by alpha-benzoin oxime modified Amberlite XAD-2000 resin.

机构信息

Department of Chemistry, Faculty of Sciences, K.N. Toosi University of Technology, Tehran 16617, Iran.

出版信息

Talanta. 2010 Jan 15;80(3):1191-7. doi: 10.1016/j.talanta.2009.09.007.

Abstract

A new solid phase extraction method for separation and preconcentration of trace amounts of uranium, thorium, and zirconium in water samples is proposed. The procedure is based on the adsorption of U(VI), Th(IV) and Zr(IV) ions on a column of Amberlite XAD-2000 resin loaded with alpha-benzoin oxime prior to their simultaneous spectrophotometric determination with Arsenazo III using orthogonal signal correction partial least squares method. The enrichment factor for preconcentration of uranium, thorium, and zirconium was found to be 100. The detection limits for U(VI), Th(IV) and Zr(IV) were 0.50, 0.54, and 0.48microgL(-1), respectively. The precision of the method, evaluated as the relative standard deviation obtained by analyzing a series of 10 replicates, was below 4% for all elements. The practical applicability of the developed sorbent was examined using synthetic seawater, natural waters and ceramic samples.

摘要

提出了一种新的固相萃取方法,用于分离和预浓缩水样中的痕量铀、钍和锆。该方法基于在 Amberlite XAD-2000 树脂柱上吸附 U(VI)、Th(IV)和 Zr(IV)离子,然后用阿散酸 III 进行同时分光光度法测定,同时使用正交信号校正偏最小二乘法。铀、钍和锆的富集因子为 100。U(VI)、Th(IV)和 Zr(IV)的检测限分别为 0.50、0.54 和 0.48μg/L。该方法的精密度,通过分析一系列 10 个重复来评估,对于所有元素均低于 4%。使用合成海水、天然水和陶瓷样品检验了所开发的吸附剂的实际适用性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验