Suppr超能文献

使用改良裂隙灯适配光学相干断层扫描成像观察小梁切除术后的后弹力层脱离。

Imaging of descemet membrane detachment after trabeculectomy using slit-lamp-adapted optical coherence tomography.

机构信息

Department of Opthalmology, Einhorn Clinical Research Center, New York Eye and Ear Infirmary, NY 10003, USA.

出版信息

J Glaucoma. 2009 Dec;18(9):643-5. doi: 10.1097/IJG.0b013e31819c469e.

Abstract

PURPOSE

To report the use of slit-lamp-adapted optical coherence tomography (SL-OCT) in imaging 2 patients with Descemet membrane detachment following anterior chamber reformation after trabeculectomy.

METHODS

Two patients, with leaking and overfiltering blebs, respectively, developed Descemet detachments after reformation of flat anterior chambers with viscoelastics. Slit-lamp biomicroscopy and SL-OCT were used to diagnose and monitor posttreatment outcome.

RESULTS

Biomicroscopic evaluation and SL-OCT imaging of the cornea revealed a Descemet detachment in both cases. One patient underwent intracameral air injection. Follow-up SL-OCT imaging revealed reattachment of Descemet membrane and reduced corneal thickness.

CONCLUSIONS

SL-OCT can be used to document and follow postsurgical detachment of Descemet membrane.

摘要

目的

报告 2 例小梁切除术后前房重建后发生的角膜后弹力层脱离(Descemet 膜脱离)患者使用裂隙灯适配光学相干断层扫描(SL-OCT)进行成像的情况。

方法

分别有 2 例患者在前房成形术中使用粘弹剂后发生渗漏和滤过过强,导致扁平前房再形成,之后发生了 Descemet 脱离。使用裂隙灯生物显微镜和 SL-OCT 对患者进行诊断并监测治疗结果。

结果

在这两种情况下,通过角膜生物显微镜检查和 SL-OCT 成像评估均发现有 Descemet 脱离。其中 1 例患者接受了眼内注气治疗。SL-OCT 随访成像显示,Descemet 膜重新附着,角膜厚度减少。

结论

SL-OCT 可用于记录和随访术后发生的 Descemet 膜脱离。

相似文献

3
Delayed-onset isolated central Descemet membrane blister detachment following phacoemulsification.
J Cataract Refract Surg. 2008 Sep;34(9):1601-3. doi: 10.1016/j.jcrs.2008.04.046.
4
The use of postoperative slit-lamp optical coherence tomography to predict primary failure in descemet stripping automated endothelial keratoplasty.
Am J Ophthalmol. 2009 May;147(5):796-800, 800.e1. doi: 10.1016/j.ajo.2008.12.015. Epub 2009 Feb 20.
6
Corneal imaging with anterior segment optical coherence tomography for lamellar keratoplasty procedures.
Am J Ophthalmol. 2008 Jan;145(1):81-90. doi: 10.1016/j.ajo.2007.08.019. Epub 2007 Oct 29.
8
Filtering bleb evaluation with slit-lamp-adapted 1310-nm optical coherence tomography.
Curr Eye Res. 2006 Nov;31(11):909-15. doi: 10.1080/02713680600910528.
9
Optical coherence tomography of Descemet membrane separation by the big bubble technique.
Cornea. 2007 Oct;26(9):1115-7. doi: 10.1097/ICO.0b013e318142bdb9.