Comparison of pumps and oxygenators with pulsatile and nonpulsatile modes in an infant cardiopulmonary bypass model.

机构信息

Pediatric Cardiac Research Laboratories, Department of Pediatrics, Hershey, PA 17033-0850, USA.

出版信息

Artif Organs. 2009 Nov;33(11):993-1001. doi: 10.1111/j.1525-1594.2009.00911.x.

Abstract

As the evidence mounts in favor of pulsatile perfusion during CPB, it is necessary to investigate the effect of circuit components on the quality of pulsatility delivered throughout the circuit. We compared two bloodpumps, the Jostra HL-20 heart-lung machine and the MEDOS DELTASTREAM DP1 Bloodpump, and two oxygenators, the Capiox Baby RX05 and the MEDOS HILITE 800LT, in terms of mean arterial pressure, energy equivalent pressure, surplus hemodynamic energy, total hemodynamic energy, and pressure drop over the oxygenators using a blood analog. The pumps and oxygenators were combined in unique circuits and tested in nonpulsatile and pulsatile modes, at two flow rates (500 and 800 mL/min), and three rotational speed differentials when using the MEDOS DELTASTREAM DP1 Bloodpump for 144 trials in total. The Jostra Roller pump produced some pulsatility in nonpulsatile mode and better pulsatility in pulsatile mode than the MEDOS DP1 Bloodpump at a rotational speed differential of 2500 rpm, but not at 3500 or 4500 rpm. The MEDOS DP1 Bloodpump produced almost no pulsatility in nonpulsatile mode. Pressure drops over the Capiox Baby RX05 were markedly higher, at 92.5 +/- 0.4 mm Hg with the MEDOS DP1 Bloodpump at 800 mL/min and 4500 rpm in pulsatile mode, than those of the MEDOS HILITE 800LT oxygenator, which was 67.0 +/- 0.1 mm Hg at the same settings. These results suggest that careful selection of each circuit component, based on the individual clinical case and component specifics, are necessary to achieve the best quality of pulsatility.

摘要

随着 CPB 期间脉动灌注的证据越来越多,有必要研究回路组件对整个回路输送的脉动质量的影响。我们比较了两种血液泵,Jostra HL-20 心肺机和 MEDOS DELTASTREAM DP1 血液泵,以及两种氧合器,Capiox Baby RX05 和 MEDOS HILITE 800LT,在使用血液模拟的情况下,比较了平均动脉压、能量等效压、剩余血液动力能量、总血液动力能量和氧合器上的压降。这些泵和氧合器被组合在独特的回路中,在非脉动和脉动模式下进行测试,流速为 500 和 800mL/min,当使用 MEDOS DELTASTREAM DP1 血液泵时,总共有 144 次试验,转速差为 2500、3500 和 4500rpm。Jostra 滚压泵在非脉动模式下产生了一些脉动,在转速差为 2500rpm 的脉动模式下比 MEDOS DP1 血液泵产生了更好的脉动,但在 3500 或 4500rpm 时则不然。MEDOS DP1 血液泵在非脉动模式下几乎没有产生脉动。Capiox Baby RX05 的压降在脉动模式下明显更高,在 MEDOS DP1 血液泵以 800mL/min 和 4500rpm 运转时为 92.5+/-0.4mmHg,而 MEDOS HILITE 800LT 氧合器在相同条件下为 67.0+/-0.1mmHg。这些结果表明,为了达到最佳的脉动质量,有必要根据个体临床病例和组件的具体情况,仔细选择每个回路组件。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验