上颈椎背侧肌肉厚度测量的可靠性:超声研究。
Reliability of thickness measurements of the dorsal muscles of the upper cervical spine: an ultrasonographic study.
机构信息
Department of Physical Medicine and Rehabilitation, National Taiwan University Hospital, Taipei, Taiwan.
出版信息
J Orthop Sports Phys Ther. 2009 Dec;39(12):850-7. doi: 10.2519/jospt.2009.3005.
STUDY DESIGN
Clinical measurement, reliability.
OBJECTIVES
To examine the intraday intrarater reliability of measuring thickness of the upper dorsal neck muscles at rest, as well as at 50% of maximum voluntary isometric contraction (MVIC), for upper cervical extension.
BACKGROUND
Methodology for measuring the thickness of the lower dorsal neck muscles, including semispinalis capitis and multifidus muscles, during contraction using ultrasonography has been established. Thickness measurements for the upper dorsal neck muscles have not been documented.
METHODS
Ten subjects (21 to 30 years of age) without neck pain and headache were recruited. Their upper dorsal neck muscles were measured both at rest and during 50% MVIC for upper cervical extension in sitting position using rehabilitative ultrasound imaging (RUSI). Muscles measured included the rectus capitis posterior major, oblique capitis superior, semispinalis capitis, and splenius capitis. All measurements were repeated after 10 minutes of rest, on the same day, by the same rater. Descriptive statistics were supplemented by calculations of intraclass correlation coefficient (ICC3,1), standard error of measurement (SEM), within-subject coefficient of variation (CVw), and minimal detectable change (MDC).
RESULTS
ICC3,1 results ranged from 0.87 to 0.99 for thickness measurements made at rest and from 0.90 to 0.98 for thickness measurements made with a 50% MVIC. The SEMs for thickness measurements at rest and at 50% MVIC ranged from 0.11 to 0.46 mm and 0.23 to 0.52 mm, while the CVws ranged from 3.5% to 6.1% and 3.7% to 6.4%, and MDC95 ranged from 0.35 to 1.46 mm and 0.73 to 1.65 mm, respectively. The thickness of all upper dorsal neck muscles measured during a 50% MVIC was greater than when measured at rest (P<.029).
CONCLUSION
Thickness measurements of the upper dorsal neck muscles using RUSI were reliable both at rest and during a 50% effort isometric contraction.
研究设计
临床测量,可靠性。
目的
检查在上颈椎伸展时,测量上背部颈部肌肉在休息时和 50%最大自主等长收缩(MVIC)时的日内同一位测者的可靠性。
背景
已经建立了使用超声测量下背部颈部肌肉(包括头半棘肌和多裂肌)在收缩期间厚度的方法。尚未记录上背部颈部肌肉的厚度测量值。
方法
招募了 10 名无颈痛和头痛的受试者(21 至 30 岁)。使用康复超声成像(RUSI)在坐姿下,分别在休息时和 50%MVIC 期间对上背部颈部肌肉进行测量。测量的肌肉包括头后大直肌、头侧上斜肌、头半棘肌和头夹肌。同一位测者在当天休息 10 分钟后重复所有测量。使用描述性统计,辅以计算组内相关系数(ICC3,1)、测量标准误差(SEM)、个体内变异系数(CVw)和最小可检测变化(MDC)。
结果
休息时和 50%MVIC 时厚度测量的 ICC3,1 结果范围分别为 0.87 至 0.99 和 0.90 至 0.98。休息时和 50%MVIC 时厚度测量的 SEM 范围分别为 0.11 至 0.46 毫米和 0.23 至 0.52 毫米,CVw 范围分别为 3.5%至 6.1%和 3.7%至 6.4%,MDC95 范围分别为 0.35 至 1.46 毫米和 0.73 至 1.65 毫米。在 50%MVIC 期间测量的所有上背部颈部肌肉的厚度均大于休息时的厚度(P<.029)。
结论
使用 RUSI 对上背部颈部肌肉的厚度进行测量,在休息时和 50%等长收缩时均具有可靠性。