Santilli Roberto A, Ferasin Luca, Voghera Simona G, Perego Manuela
Clinica Veterinaria Malpensa, Via Marconi, 27, 21017 Samarate, Varese, Italy.
J Am Vet Med Assoc. 2010 Jan 1;236(1):78-82. doi: 10.2460/javma.236.1.78.
To evaluate the diagnostic value of an implantable loop recorder (ILR) in dogs with unexplained syncope.
Prospective case series.
12 dogs with recurrent unexplained syncope.
An ILR was surgically inserted in a pocket created in the subcutaneous tissues of the left hemithorax of each dog. The ILRs were programmed for manual and automatic activation, and event analysis and programming were performed at 3-month intervals and after each syncopal episode.
The ILR was manually activated in 7 of 12 dogs at least once within 45 to 218 days (median, 120 days) after implantation. Four dogs had syncopal episodes associated with sinus tachycardia followed by sinus bradycardia and asystolic pauses. Two dogs had ventricular tachycardia, and 1 dog had sinus node dysfunction with prolonged sinus arrest that coincided with loss of consciousness and falling. Four dogs had no additional syncopal episodes after implantation of the ILR. In the remaining dog, the owner was unable to activate the ILR during the only syncopal episode observed for that dog after ILR implantation. In all 12 dogs, analysis of ECG traces after automatic activation of recording revealed normal cardiac rhythms.
Data gained after manual activation of an ILR provided valuable diagnostic and prognostic information in almost all dogs with unexplained syncopal episodes by confirming or disproving an association between syncope and arrhythmias. However, detection of disturbances in cardiac rhythm after automatic activation did not appear to improve the diagnostic value for an ILR implanted in dogs.
评估植入式循环记录仪(ILR)对不明原因晕厥犬的诊断价值。
前瞻性病例系列研究。
12只反复出现不明原因晕厥的犬。
在每只犬左半胸皮下组织创建的囊袋中手术植入ILR。ILR设置为手动和自动激活模式,每3个月以及每次晕厥发作后进行事件分析和程序设定。
12只犬中有7只在植入后45至218天(中位数为120天)内至少手动激活ILR一次。4只犬的晕厥发作与窦性心动过速后窦性心动过缓和心搏停止有关。2只犬出现室性心动过速,1只犬出现窦房结功能障碍伴窦性停搏延长,与意识丧失和跌倒同时发生。4只犬植入ILR后未再出现晕厥发作。在剩下的1只犬中,主人在ILR植入后观察到的唯一一次晕厥发作期间无法激活ILR。在所有12只犬中,自动激活记录后的心电图分析显示心律正常。
通过证实或否定晕厥与心律失常之间的关联,手动激活ILR后获得的数据为几乎所有不明原因晕厥发作的犬提供了有价值的诊断和预后信息。然而,自动激活后检测到的心律紊乱似乎并未提高植入犬的ILR的诊断价值。