Gallo C F
Xerox Research Laboratories, Rochester,New York 14603, USA.
Appl Opt. 1967 Sep 1;6(9):1563-5. doi: 10.1364/AO.6.001563.
The addition of metallic iodides to mercury arc lamps has proven to be an effective and practical method of altering the spectral output. If the excitation levels of the metal of the dissociated iodide are lower than the excitation levels of mercury, the mercury arc temperature is considerably reduced. Experimental evidence for this phenomenon is presented.
向汞弧灯中添加金属碘化物已被证明是改变光谱输出的一种有效且实用的方法。如果离解碘化物中金属的激发能级低于汞的激发能级,汞弧温度会显著降低。本文给出了这一现象的实验证据。