Abstract

A technique is described to measure the electron density distribution of a high temperature plasma, produced in a theta-pinch, by observing the bremsstrahlung continuum radiation emitted. Streak cameras record simultaneously the visible light emitted at three axial positions. The photographic film is calibrated using ashort duration flash and a step filter, and densitometer scans give the relative intensities. The data gives the raidal intensity distribution, from which the electron density distribution may be calculated. Estimated accuracy of the density measurement is +/-25%.

摘要

描述了一种通过观察发射的轫致辐射连续谱来测量在θ箍缩装置中产生的高温等离子体电子密度分布的技术。条纹相机同时记录在三个轴向位置发射的可见光。使用短持续时间闪光灯和阶梯滤波器对摄影胶片进行校准,密度计扫描给出相对强度。这些数据给出了径向强度分布,由此可以计算出电子密度分布。密度测量的估计精度为±25%。