Department of Psychiatry, University of Colorado Denver, Anschutz, Medical Campus, MS F-546, 13001 E 17th Pl., Aurora, CO 80045, USA.
Clin Neurophysiol. 2010 Apr;121(4):542-8. doi: 10.1016/j.clinph.2009.12.010. Epub 2010 Jan 13.
To study the phase stability of the 40Hz auditory steady-state response (ASSR) in Sz, and in addition, to investigate inter-hemispheric phase synchronization using ipsilateral and contralateral hemisphere gamma band ASSRs.
Whole head magnetoencephalography (MEG) was used to detect ASSR from both hemispheres in Sz patients and their control counterparts. Source localization, spatial and temporal filtering were performed to infer gamma band activity from the neural generators of the ASSR. The response gamma band phase stability relative to a reference signal was quantified using the phase synchronization index (PSI).
Results indicated reduced phase synchronization of the ASSR and the stimulus reference signal in Sz patients compared to control subjects, in addition to reduced inter-hemispheric phase synchronization between contralateral and ipsilateral hemispheric responses in Sz patients.
Greater intra and inter hemispheric fluctuations of ASSR gamma band phase synchronization in Sz add to previous studies suggesting timing deficiencies within neural populations, possibly caused by impairments of neural network parameters.
This study provides experimental support that may aid in understanding the dynamics of neural phase synchrony caused by modifications of underlying neurotransmitter systems, as reflected in disease states such as schizophrenia.
研究 Sz 患者 40Hz 听觉稳态反应(ASSR)的相位稳定性,并利用同侧和对侧半球γ频段 ASSR 研究半球间的相位同步。
使用全头脑磁图(MEG)从 Sz 患者及其对照组的两个半球检测 ASSR。进行源定位、空间和时间滤波,从 ASSR 的神经发生器推断出γ频段活动。使用相位同步指数(PSI)量化相对于参考信号的反应γ频段相位稳定性。
结果表明,与对照组相比,Sz 患者的 ASSR 和刺激参考信号的相位同步性降低,此外,Sz 患者对侧和同侧半球反应之间的半球间相位同步性也降低。
Sz 患者 ASSR γ 频段相位同步的内和间半球波动增加,这与先前的研究表明,神经群体内的定时缺陷可能是由于神经网络参数的损伤所致,这一研究提供了实验支持。
这项研究提供了实验支持,可能有助于理解由基础神经递质系统改变引起的神经相位同步的动力学,这种改变反映在精神分裂症等疾病状态中。