Background intracranial EEG spectral changes with anti-epileptic drug taper.

机构信息

Department of Neurology, Yale University, New Haven, CT 06520, USA.

出版信息

Clin Neurophysiol. 2010 Mar;121(3):311-7. doi: 10.1016/j.clinph.2009.11.081. Epub 2010 Jan 13.

Abstract

OBJECTIVE

Previous studies have revealed a surprising decrease in spike counts and Teager energy between on- and off-AEDs states during intracranial EEG (icEEG) monitoring. Here, we expand the measures evaluated to icEEG power and frequency band power.

METHODS

Two icEEG epochs, on- and off-AEDs, each 1h in duration, were studied for each of 21 unselected adult patients. Spike counts, Teager energy and total power were evaluated for each electrode contact. Power was also evaluated for delta (0-4Hz), theta (4-8Hz), alpha (8-13Hz), beta (13-25Hz), gamma (25-55Hz) and high (65-128Hz) frequency bands.

RESULTS

A decrease in power accompanies AED taper and the previously reported decrease in spike counts and Teager energy. The decrease in power was underpinned by a spatially widespread and broadband decrease in power in delta through gamma frequency bands with maximum decrease in the lowest frequency bands. An increase in high-frequency power was observed in some patients.

CONCLUSIONS

There is a decrease in spike counts, Teager energy and power from on- to off-AEDs state during intracranial monitoring. The decrease in power is spatially widespread and broadband including power in the delta through gamma frequency bands.

SIGNIFICANCE

The decrease in cortical activity with AED taper suggests that seizure generation during intracranial monitoring may not be mediated solely by poorly regulated cortical excitation.

摘要

目的

先前的研究表明,在颅内脑电图(icEEG)监测期间,AED 开启与关闭状态之间的尖峰计数和 Teager 能量惊人地减少。在这里,我们将评估的措施扩展到 icEEG 功率和频带功率。

方法

对 21 名未选择的成年患者的每例患者进行 2 个 icEEG 时段(开启 AED 和关闭 AED 各 1 小时)的研究。评估每个电极接触的尖峰计数、Teager 能量和总功率。还评估了 delta(0-4Hz)、theta(4-8Hz)、alpha(8-13Hz)、beta(13-25Hz)、gamma(25-55Hz)和 high(65-128Hz)频带的功率。

结果

随着 AED 逐渐减少,以及之前报道的尖峰计数和 Teager 能量减少,功率下降。功率下降的原因是 delta 至 gamma 频带的功率在空间上广泛且宽带下降,最低频带的下降幅度最大。一些患者观察到高频功率增加。

结论

在颅内监测期间,从开启 AED 到关闭 AED 状态,尖峰计数、Teager 能量和功率均下降。功率下降是空间广泛且宽带的,包括 delta 至 gamma 频带的功率。

意义

随着 AED 逐渐减少,皮质活动减少表明颅内监测期间的癫痫发作可能不仅仅是由皮质兴奋调节不良引起的。