• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits.

作者信息

Videm V, Mollnes T E, Garred P, Svennevig J L

机构信息

Institute for Experimental Medical Research, Ullevaal Hospital, Oslo, Norway.

出版信息

J Thorac Cardiovasc Surg. 1991 Apr;101(4):654-60.

PMID:2008104
Abstract

Oxygenator/tubing sets coated with endpoint-attached heparin were compared to uncoated sets in a dynamic model of extracorporeal circulation. Biocompatibility was assessed by evaluations of complement activation and platelet loss. The median concentration of C3 activation products increased gradually from 12 AU/ml at baseline to 65 AU/ml after 120 minutes in the uncoated sets and from 12 AU/ml to 19 AU/ml after 120 minutes in the coated sets (p less than 0.002). The median concentration of the terminal complement complex in the uncoated sets increased gradually from 3.1 AU/ml at baseline to 18.2 AU/ml after 120 minutes. In the coated sets the terminal complement complex reached a peak of 12.0 AU/ml at 15 minutes and returned to baseline values at 60 minutes. Median platelet loss at 120 minutes was 166 x 10(9) in the uncoated and 21 x 10(9) in the coated sets (p less than 0.01). Heparin coating thus improved biocompatibility by reducing both complement activation and platelet loss.

摘要

相似文献

1
Biocompatibility of extracorporeal circulation. In vitro comparison of heparin-coated and uncoated oxygenator circuits.
J Thorac Cardiovasc Surg. 1991 Apr;101(4):654-60.
2
Complement activation during extracorporeal circulation. In vitro comparison of Duraflo II heparin-coated and uncoated oxygenator circuits.体外循环期间的补体激活。Duraflo II肝素涂层与未涂层氧合器回路的体外比较。
J Thorac Cardiovasc Surg. 1993 Sep;106(3):466-72.
3
In vitro evaluation of new surface coatings for extracorporeal circulation.体外循环新表面涂层的体外评估
Perfusion. 1999 Jan;14(1):11-9. doi: 10.1177/026765919901400103.
4
Reduced complement activation with heparin-coated oxygenator and tubings in coronary bypass operations.在冠状动脉搭桥手术中使用肝素涂层氧合器和管道可减少补体激活。
J Thorac Cardiovasc Surg. 1992 Apr;103(4):806-13.
5
Comparison of three oxygenator-coated and one total-circuit-coated extracorporeal devices.三种氧合器涂层和一种全回路涂层体外装置的比较。
Perfusion. 1999 Mar;14(2):119-27. doi: 10.1177/026765919901400205.
6
Centrifugal pump and heparin coating improves cardiopulmonary bypass biocompatibility.离心泵和肝素涂层可改善体外循环的生物相容性。
Ann Thorac Surg. 1996 Oct;62(4):1134-40. doi: 10.1016/0003-4975(96)00492-4.
7
Extracorporeal circulation: in vivo and in vitro analysis of complement activation by heparin-bonded surfaces.
Circ Shock. 1993 Jul;40(3):221-6.
8
Biomaterial-dependent blood activation during simulated extracorporeal circulation: a study of heparin-coated and uncoated circuits.模拟体外循环期间生物材料依赖性血液激活:肝素涂层和未涂层回路的研究
Thorac Cardiovasc Surg. 1997 Dec;45(6):295-301. doi: 10.1055/s-2007-1013752.
9
Heparin-coated circuits reduce complement activation and inflammatory response to cardiopulmonary bypass.肝素涂层回路可减少体外循环时的补体激活和炎症反应。
Panminerva Med. 1999 Sep;41(3):193-8.
10
Platelet compatibility of an artificial surface modified with functionally active heparin.具有功能活性肝素修饰的人工表面的血小板相容性。
Thromb Haemost. 1999 Sep;82(3):1132-6.

引用本文的文献

1
Plasma proteomic changes during hypothermic and normothermic cardiopulmonary bypass in aortic surgeries.主动脉手术中低温与常温体外循环期间的血浆蛋白质组学变化
Int J Mol Med. 2014 Oct;34(4):947-56. doi: 10.3892/ijmm.2014.1855. Epub 2014 Jul 15.