AIM

The cardiac output and coronary perfusion pressure generated from chest compressions during resuscitation manoeuvres can predict effectiveness and successful outcome. Until now, there is no good method for haemodynamic monitoring during resuscitation. Noninvasive partial carbon dioxide rebreathing system (NICO, Novametrix Medical Systems, Inc., Wallingford, CT, USA) is a relatively new non-invasive alternative to thermodilution for measuring cardiac output. The accuracy of the NICO system has not been evaluated during resuscitation. The aim of this study is to compare thermodilution cardiac output method with NICO system and to assess the utility of NICO during resuscitation.

METHODS AND DESIGN

Experimental study in 24 Yorkshire pigs. Paired measurements of cardiac output were determined during resuscitation (before ventricular fibrillation and after 5, 15, 30 and 45 min of resuscitation) in the supine position. The average of 3 consecutive thermodilution cardiac output measurements (10 ml 20 degrees C saline) was compared with the corresponding NICO measurement.

RESULTS

Bland and Altman plot and Lin's concordance coefficient showed a high correlation between NICO and thermodilution cardiac output measurements although NICO has a tendency to underestimate cardiac output when compared to thermodilution at normal values of cardiac output.

CONCLUSIONS

There is a high degree of agreement between cardiac output measurements obtained with NICO and thermodilution cardiac output during resuscitation. The present study suggests that the NICO system may be useful to measure cardiac output generated during cardiopulmonary resuscitation.

摘要

目的

复苏过程中的胸外按压产生的心输出量和冠状动脉灌注压可以预测复苏的效果和成功结局。到目前为止,还没有用于复苏期间血流动力学监测的好方法。非侵入性部分二氧化碳重呼吸系统(NICO,美国诺瓦梅特里克斯医疗系统公司,Wallingford,CT)是一种相对较新的、用于测量心输出量的替代热稀释法的非侵入性方法。NICO 系统的准确性在复苏期间尚未得到评估。本研究的目的是比较热稀释法心输出量与 NICO 系统,并评估 NICO 在复苏期间的实用性。

方法和设计

在 24 头约克夏猪中进行实验研究。在仰卧位下,在复苏期间(心室颤动前和复苏后 5、15、30 和 45 分钟)进行心输出量的配对测量。将 3 次连续热稀释心输出量测量(10ml20°C 生理盐水)的平均值与相应的 NICO 测量值进行比较。

结果

Bland 和 Altman 图和 Lin 的一致性系数显示,NICO 与热稀释心输出量测量之间具有高度相关性,尽管在正常心输出量值下,NICO 与热稀释相比有低估心输出量的趋势。

结论

在复苏过程中,NICO 和热稀释心输出量测量之间具有高度的一致性。本研究表明,NICO 系统可能有助于测量心肺复苏过程中产生的心输出量。