Suppr超能文献

甲状腺相关眼病眶减压术后眼外肌容积变化的影像学分析。

Radiographic analysis of extraocular muscle volumetric changes in thyroid-related orbitopathy following orbital decompression.

机构信息

USCD Department of Ophthalmology, University of California, San Diego School of Medicine, La Jolla, California 92093, USA.

出版信息

Ophthalmic Plast Reconstr Surg. 2010 Jan-Feb;26(1):1-6. doi: 10.1097/IOP.0b013e3181b80fae.

Abstract

PURPOSE

To evaluate radiographic volume changes in extraocular muscles (EOM) following orbital decompression for thyroid-related orbitopathy (TRO).

METHODS

Medical records of 22 orbits in 12 patients undergoing postoperative orbital CT after orbital decompression for TRO were retrospectively reviewed. All orbits demonstrated no signs of clinical reactivation of TRO. EOM volumes were determined by the summation of each EOM's cross-sectional area in the coronal plane of the CT scans and multiplying the sum by the slice thickness. Main outcome measure was a comparison of EOM volumes preoperatively and postoperatively.

RESULTS

All orbits demonstrated proptosis reduction postoperatively with a mean of 4.8 mm +/- 2.1 mm (p < 0.0001). The significant increase in the medial rectus muscle (p = 0.0010) postoperatively accounted for the primary change in the postoperative enlargement of total EOM volume (p = 0.028). The medial rectus muscle increased 27% from the preoperative volume. The lateral rectus, superior rectus/levator complex, inferior rectus, and superior oblique muscles did not demonstrate a significant volume increase postoperatively (p = 0.23, 0.21, 0.17, 0.40, respectively). Two patients who underwent unilateral orbital decompression demonstrated EOM enlargement postoperatively in the operative orbit only.

CONCLUSIONS

There is a significant increase in medial rectus muscle volume postoperatively in orbits undergoing orbital decompression for TRO despite lacking clinical evidence of disease reactivation.

摘要

目的

评估甲状腺相关眼病(TRO)行眼眶减压术后眼外肌(EOM)的放射学体积变化。

方法

回顾性分析了 12 例 TRO 患者 22 只眼眶行眼眶减压术后行眼眶 CT 检查的病历。所有眼眶均无 TRO 临床再活动的迹象。通过冠状位 CT 扫描中每个 EOM 的横截面积之和乘以切片厚度来确定 EOM 体积。主要观察指标是术前和术后 EOM 体积的比较。

结果

所有眼眶在术后均显示眼球突出度减小,平均为 4.8mm±2.1mm(p<0.0001)。术后内侧直肌显著增加(p=0.0010),是总 EOM 体积术后增大的主要原因(p=0.028)。内侧直肌从术前体积增加了 27%。术后外侧直肌、上直肌/提肌复合体、下直肌和上斜肌体积均无明显增加(p=0.23、0.21、0.17、0.40)。2 例行单侧眼眶减压术的患者仅在手术眼眶中出现术后 EOM 增大。

结论

尽管缺乏疾病再活动的临床证据,但 TRO 行眼眶减压术后,内侧直肌体积仍显著增加。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验