Department of Orthopaedic Surgery, University of South Florida, Tampa, FL 33612, USA.
J Arthroplasty. 2010 Jun;25(4):654-7. doi: 10.1016/j.arth.2009.11.002. Epub 2010 Jan 22.
Hip joint dislocation is the most common complication after proximal femoral arthroplasty with a large endoprosthesis. Average dislocation rates are around 15%. In an attempt to decrease dislocations after proximal femoral arthroplasty for tumor resections, we devised a novel closure of the hip capsule. This technique uses a 3-mm cottony Dacron suture placed about the hip capsule in a circumferential, purse-string manner. Thirty-nine patients received hip hemiarthroplasty with purse-string capsular closure. Seven patients were lost to follow-up, leaving 36 patients available for analysis. One patient dislocated (2.8%). We believe this technique is useful in preventing dislocation in patients undergoing proximal femoral arthroplasty for oncologic disease.