Department of Prosthodontics, University of Alabama School of Dentistry, Birmingham, AL 35294, USA.
J Prosthodont. 2010 Jun;19(4):299-302. doi: 10.1111/j.1532-849X.2009.00564.x. Epub 2010 Jan 22.
A patient presenting with severe microstomia (PDI Class IV) was unable to insert a maxillary complete denture. Sectional final impressions were made using two impression materials and an interlocking custom tray. A folding record base was used for maxillomandibular relationship records. A novel folding maxillary denture with a custom hinge and plunger attachment to lock the denture in the open position was fabricated. The patient was able to insert the collapsed denture, open it intraorally, and enjoy successful masticatory function.
一位患有严重小口畸形(PDI 分级 IV)的患者无法插入上颌全口义齿。使用两种印模材料和一个互锁式定制托盘进行分段最终印模。使用折叠记录基托进行上颌下颌关系记录。制作了一种带有定制铰链和柱塞附件的新型折叠上颌义齿,可将义齿锁定在打开位置。患者能够插入塌陷的义齿,在口腔内打开它,并享受成功的咀嚼功能。