[Assessment of the usefulness to use a software supervising continuous infusion rates of drugs administered with pumps in ICU and estimation of the frequency of rate of administration errors].

作者信息

Cayot-Constantin S, Constantin J-M, Perez J-P, Chevallier P, Clapson P, Bazin J-E

机构信息

Service d'anesthésie-réanimation, Hôtel-Dieu, CHU de Clermont-Ferrand, boulevard L.-Malfreyt, 63058 Clermont-Ferrand, France.

出版信息

Ann Fr Anesth Reanim. 2010 Mar;29(3):204-8. doi: 10.1016/j.annfar.2009.10.025. Epub 2010 Feb 1.

DOI:10.1016/j.annfar.2009.10.025
PMID:20117909
Abstract

OBJECTIVES

To assess the usefulness and the feasibility to use a software supervising continuous infusion rates of drugs administered with pumps in ICU.

STUDY DESIGN

Follow-up of practices and inquiry in three intensive care units.

MATERIAL

Guardrails software(TM) of reassurance of the regulations of the rates of pumps (AsenaGH, Alaris).

METHODS

First, evaluation and quantification of the number of infusion-rates adjustments reaching the maximal superior limit (considered as infusion-rate-errors stopped by the software). Secondly, appreciate the acceptance by staffs to such a system by a blinded questionnaire and a quantification of the number of dataset pumps programs performed with the software.

RESULTS

The number of administrations started with the pumps of the study in the three services (11 beds) during the period of study was 63,069 and 42,694 of them (67.7 %) used the software. The number of potential errors of continuous infusion rates was 11, corresponding to a rate of infusion-rate errors of 26/100,000. KCl and insulin were concerned in two and five cases, respectively. Eighty percent of the nurses estimated that infusion-rate-errors were rare or exceptional but potentially harmful. Indeed, they considered that software supervising the continuous infusion rates of pumps could improve safety.

CONCLUSION

The risk of infusion-rate-errors of drugs administered continuously with pump in ICU is rare but potentially harmful. A software that controlled the continuous infusion rates could be useful.

摘要

相似文献

1
[Assessment of the usefulness to use a software supervising continuous infusion rates of drugs administered with pumps in ICU and estimation of the frequency of rate of administration errors].
Ann Fr Anesth Reanim. 2010 Mar;29(3):204-8. doi: 10.1016/j.annfar.2009.10.025. Epub 2010 Feb 1.
2
Developing a drug library for smart pumps in a pediatric intensive care unit.开发儿科重症监护病房智能输液泵药物库。
Artif Intell Med. 2012 Mar;54(3):155-61. doi: 10.1016/j.artmed.2011.12.001. Epub 2012 Jan 4.
3
Impact of computerized orders for pediatric continuous drug infusions on detecting infusion pump programming errors: a simulated study.计算机化医嘱对小儿持续药物输注中输液泵编程错误检测的影响:一项模拟研究。
J Pediatr Nurs. 2010 Apr;25(2):108-18. doi: 10.1016/j.pedn.2008.10.002. Epub 2009 Apr 8.
4
Standard drug concentrations and smart-pump technology reduce continuous-medication-infusion errors in pediatric patients.标准药物浓度和智能输液泵技术可减少儿科患者连续药物输注错误。
Pediatrics. 2005 Jul;116(1):e21-5. doi: 10.1542/peds.2004-2452.
5
Impact of implementing smart infusion pumps in a pediatric intensive care unit.在儿科重症监护病房实施智能输液泵的影响。
Am J Health Syst Pharm. 2013 Nov 1;70(21):1897-906. doi: 10.2146/ajhp120767.
6
Insights from the sharp end of intravenous medication errors: implications for infusion pump technology.静脉用药错误尖锐问题的见解:对输液泵技术的启示。
Qual Saf Health Care. 2005 Apr;14(2):80-6. doi: 10.1136/qshc.2004.011957.
7
Feasibility of infusion pumps for continuous spinal administration of local anesthetics in post-operative pain therapy.术后疼痛治疗中用于持续脊髓给药局部麻醉剂的输注泵的可行性。
Acta Anaesthesiol Scand. 2009 May;53(5):634-40. doi: 10.1111/j.1399-6576.2009.01928.x.
8
Medication administration errors in adult patients in the ICU.重症监护病房成年患者的用药错误
Intensive Care Med. 2001 Oct;27(10):1592-8. doi: 10.1007/s001340101065.
9
Implementation of an intravenous medication infusion pump system: implications for nursing.静脉用药输注泵系统的实施:对护理的影响
J Nurs Manag. 2008 Mar;16(2):188-97. doi: 10.1111/j.1365-2834.2007.00809.x.
10
Smart pump alerts: all that glitters is not gold.智能输液泵警示:并非所有闪光的都是金子。
Int J Med Inform. 2012 May;81(5):344-50. doi: 10.1016/j.ijmedinf.2011.10.010. Epub 2011 Nov 9.

引用本文的文献

1
The Impact of Automation and Digitalization in Hospital Medication Management: Economic Analysis in the European Countries.自动化与数字化在医院药物管理中的影响:欧洲国家的经济分析
Healthcare (Basel). 2025 Jul 4;13(13):1604. doi: 10.3390/healthcare13131604.