Suppr超能文献

种植体间距离和植入深度对相邻即刻负载 Morse 锥度连接种植体周围骨重塑的影响:犬的组织形态计量学研究。

Influence of interimplant distances and placement depth on peri-implant bone remodeling of adjacent and immediately loaded Morse cone connection implants: a histomorphometric study in dogs.

机构信息

Department of Bucco-Maxillo-Facial Surgery and Traumatology and Periodontology, School of Dentistry of Ribeirão Preto, University of São Paulo, São Paulo, SP, Brazil.

出版信息

Clin Oral Implants Res. 2010 Apr 1;21(4):371-8. doi: 10.1111/j.1600-0501.2009.01860.x. Epub 2010 Feb 1.

Abstract

OBJECTIVES

The aim of this study was to histomorphometrically evaluate the influence of interimplant distances (ID) and implant placement depth on bone remodeling around contiguous Morse cone connection implants with 'platform-shifting' in a dog model.

MATERIAL AND METHODS

Bilateral mandibular premolars of six dogs were extracted, and after 12 weeks, each dog received 8 implants, four placed 1.5 mm subcrestally (SCL) on one side of the mandible and four placed equicrestally (ECL) on the other side, alternating the ID of 2 and 3 mm. The experimental groups were SCL with IDs of 2 mm (2 SCL) and 3 mm (3 SCL) and ECL with IDs of 2 mm (2 ECL) and 3 mm (3 ECL). Metallic crowns were immediately installed. After 8 weeks, the animals were euthanized and histomorphometric analyses were performed to compare bone remodeling in the groups.

RESULTS

The SCL groups' indices of crestal bone resorption were significantly lower than those of ECL groups. In addition, the vertical bone resorption around the implants was also numerically inferior in the SCL groups, but without statistical significance. No differences were obtained between the different IDs. All the groups presented similar good levels of bone-to-implant contact and histological bone density.

CONCLUSION

The subcrestal placement of contiguous Morse cone connection implants with 'platform shifting' was more efficient in preserving the interimplant crestal bone. The IDs of 2 and 3 mm did not affect the bone remodeling significantly under the present conditions.

摘要

目的

本研究旨在通过组织形态计量学评估种植体间距离(ID)和种植体植入深度对具有“平台转移”的连续莫尔斯锥连接种植体周围骨改建的影响。

材料和方法

六只狗的双侧下颌前磨牙被拔出,12 周后,每只狗接受 8 个种植体,4 个种植体在一侧下颌骨的颊侧骨嵴下 1.5mm(SCL),4 个种植体在另一侧下颌骨的颊侧骨嵴水平(ECL),交替 ID 为 2mm 和 3mm。实验组为 SCL 2mm(2SCL)和 3mm(3SCL)和 ECL 2mm(2ECL)和 3mm(3ECL)。立即安装金属冠。8 周后,处死动物并进行组织形态计量学分析,以比较各组的骨改建情况。

结果

SCL 组的颊侧骨吸收指数明显低于 ECL 组。此外,SCL 组的种植体周围垂直骨吸收也较低,但无统计学意义。不同 ID 之间无差异。所有组均表现出相似的良好的骨-种植体接触和组织学骨密度。

结论

在“平台转移”的情况下,连续莫尔斯锥连接种植体的颊侧骨下放置更有效地保留了种植体间的颊侧骨。在本研究条件下,ID 为 2mm 和 3mm 对骨改建没有明显影响。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验