Electroglottogram approximate entropy: a novel single parameter for objective voice assessment.

作者信息

Douglas C M, Moore C, Manickam K, Lee L, Sykes A, Carr A, Jones S, Jones J, Swindell R, Homer J J, Slevin N

机构信息

Department of Head and Neck Surgery, Christie Hospital NHS Trust, Manchester, UK.

出版信息

J Laryngol Otol. 2010 May;124(5):520-8. doi: 10.1017/S0022215109992787. Epub 2010 Feb 4.

Abstract

BACKGROUND

The electroglottogram approximate entropy value is a numerical variable which gives an overall measure of voice quality. It is derived by analysing the complexity of the electroglottogram waveform using regulatory statistics.

AIMS

(1) To use electroglottogram approximate entropy to measure voice quality in patients with glottic pathology and in normal subjects, to ascertain whether this parameter can distinguish between pathological and normal voices. (2) To ascertain whether electroglottogram approximate entropy can measure voice change over time within individual subjects. (3) To determine any correlation between electroglottogram approximate entropy and the grade-roughness-breathiness-asthenia-strain scale.

METHODS

One hundred and forty-one normal volunteers were recruited to characterise electroglottogram approximate entropy in the normal voice. One hundred and eighty-six patients with glottic squamous cell carcinoma underwent electroglottogram approximate entropy measurement prior to radiotherapy and then three to six months and one year after treatment. Subjects' voices were categorised by a speech therapist using the grade-roughness-breathiness-asthenia-strain scale.

RESULTS

The mean electroglottogram approximate entropy of the normal volunteers was 0.302 (range 0.05-0.42). The mean electroglottogram approximate entropy of the glottic squamous cell carcinoma patients was significantly lower prior to treatment, at 0.227 (range 0.001-0.397; p < 0.0005), but improved after radiotherapy to 0.277 at three to six months and 0.282 at one year. Electroglottogram approximate entropy results correlated significantly with grade-roughness-breathiness-asthenia-strain scale results.

CONCLUSION

Electroglottogram approximate entropy can be used to assess change in voice quality resulting from glottic morphological abnormality. Electroglottogram approximate entropy values improve as voice quality improves after treatment. Electroglottogram approximate entropy values correlate significantly with grade-roughness-breathiness-asthenia-strain scale results.

摘要

背景

电声门图近似熵值是一个数值变量,可对嗓音质量进行整体测量。它是通过使用调节统计分析电声门图波形的复杂性得出的。

目的

(1)用电声门图近似熵测量声门病变患者和正常受试者的嗓音质量,以确定该参数能否区分病理性嗓音和正常嗓音。(2)确定电声门图近似熵能否测量个体受试者随时间的嗓音变化。(3)确定电声门图近似熵与粗糙度-气息声-无力-紧张量表之间的相关性。

方法

招募141名正常志愿者以确定正常嗓音的电声门图近似熵特征。186名声门鳞状细胞癌患者在放疗前、治疗后三至六个月和一年进行电声门图近似熵测量。言语治疗师使用粗糙度-气息声-无力-紧张量表对受试者的嗓音进行分类。

结果

正常志愿者的平均电声门图近似熵为0.302(范围0.05 - 0.42)。声门鳞状细胞癌患者治疗前的平均电声门图近似熵显著较低,为0.227(范围0.001 - 0.397;p < 0.0005),但放疗后三至六个月提高到0.277,一年时提高到0.282。电声门图近似熵结果与粗糙度-气息声-无力-紧张量表结果显著相关。

结论

电声门图近似熵可用于评估声门形态异常导致的嗓音质量变化。治疗后随着嗓音质量改善,电声门图近似熵值升高。电声门图近似熵值与粗糙度-气息声-无力-紧张量表结果显著相关。