Cardiac Arrhythmia Services of the Mount Sinai Hospital, New York, New York 10029, USA.
J Cardiovasc Electrophysiol. 2010 Jul;21(7):731-7. doi: 10.1111/j.1540-8167.2009.01703.x. Epub 2010 Feb 1.
Because of its technical feasibility and presumed safety benefits, balloon cryoablation is being increasingly employed for pulmonary vein (PV) isolation. While acute isolation has been demonstrated in most patients, little data are available on the chronic durability of cryoballoon lesions.
Twelve atrial fibrillation patients underwent PV isolation using either a 23-mm or 28-mm cryoballoon. For each vein, after electrical isolation was verified with the use of a circular mapping cathether, 2 bonus balloon ablation lesions were placed. Gaps in balloon occlusion were overcome using either a spot cryocatheter or a "pull-down" technique. A prespecified second procedure was performed at 8-12 weeks to assess for long-term PV isolation. Acute PV isolation was achieved in all PVs in the patient cohort (n = 48 PVs), using the cryoballoon alone in 47/48 PVs (98%); a "pull-down" technique was employed for 5 PVs (1 right superior pulmonary vein, 2 right inferior pulmonary veins, and 2 left inferior pulmonary veins). The gap in the remaining vein was ablated with a spot cryocatheter. During the second mapping procedure, 42 of 48 PVs (88%) remained isolated. One vein had reconnected in 2 patients, while 2 veins had reconnected in another 2 patients. All PVs initially isolated with the "pull-down" technique remained isolated at the second procedure.
Cryoballoon ablation allows for durable PV isolation with the use of a single balloon. With maintained chronic isolation in most PVs, it may represent a significant step toward consistent and lasting ablation procedures.
由于技术可行性和预期的安全益处,球囊冷冻消融术越来越多地用于肺静脉(PV)隔离。虽然大多数患者均实现了即刻隔离,但关于冷冻球囊消融损伤的慢性持久性的数据很少。
12 例房颤患者采用 23-mm 或 28-mm 冷冻球囊进行 PV 隔离。对于每条静脉,在使用环形标测导管确认电隔离后,放置 2 个额外的球囊消融损伤。通过使用点状冷冻导管或“下拉”技术克服球囊闭塞的间隙。在 8-12 周时进行预定的第二次手术,以评估长期的 PV 隔离情况。在患者队列中的 48 个 PV 中(n = 48 PVs),所有的 PV 均实现了即刻隔离(n = 48),单独使用冷冻球囊在 47/48 PVs 中(98%)实现了即刻隔离;对于 5 个 PV (1 个右肺上静脉、2 个右肺下静脉和 2 个左肺下静脉)采用了“下拉”技术。其余静脉的间隙用点状冷冻导管消融。在第二次标测过程中,48 个 PVs 中有 42 个(88%)保持隔离。2 例患者中有 1 条静脉再通,2 例患者中有 2 条静脉再通。在第二次手术中,最初使用“下拉”技术隔离的所有 PVs均保持隔离。
冷冻球囊消融术可实现单个球囊的持久 PV 隔离。在大多数 PVs 中保持慢性隔离,这可能是实现一致和持久消融的重要一步。