基于杯芳烃离子载体的汞检测用离子选择型聚合物膜电极的研制

Potentiometric polymeric membrane electrodes for mercury detection using calixarene ionophores.

机构信息

Department of Chemistry, Faculty of Natural Sciences, Jamia Millia Islamia (Central University), New Delhi 110025, India.

出版信息

Water Sci Technol. 2010;61(3):693-704. doi: 10.2166/wst.2010.860.

Abstract

It is here established that potentiometric polymeric membrane electrodes based on electrically neutral ionophores are a useful analytical tool for the detection of heavy metal ions from environmental and industrial waste water. PVC based membrane containing p-tert-butyl-calix[4]arenethioether derivative as active material along with sodiumtetraphenylborate (NaTPB) as solvent mediator and dibutylphthalate as a plasticizer in the ratio 45:9:460:310 (w/w%) (I:NaTPB:DBP:PVC) exhibits good properties with a Nernstian response of 29.50+/-1.0 mV per decade of activity and a working concentration range of 7.2 x 10(-8)-1.0 x 10(-1) M. The electrode gave more stable potential readings when used around pH 2.5-6.8 and exhibits fast response time of 14 s. The sensors were found to work satisfactorily in partially non-aqueous media up to 40% (v/v) content of acetone, methanol or ethanol and could be used over a period of 7-9 months. Excellent selectivity for Hg(2+) ions is indicated by match potential method and fixed interference method. The sensors could be used successfully in the estimation of mercury in different sample.

摘要

现已确定,基于中性离子载体的电位型聚合膜电极是一种用于检测环境和工业废水中重金属离子的有用分析工具。以聚氯乙烯(PVC)为基质,其中包含 p-叔丁基-杯[4]芳烃硫醚衍生物作为活性物质,以及四苯硼酸钠(NaTPB)作为溶剂介导物和邻苯二甲酸二丁酯(DBP)作为增塑剂,其比例为 45:9:460:310(w/w%)(I:NaTPB:DBP:PVC)具有良好的性能,其活度每增加一个十进制数,响应值为 29.50+/-1.0 mV,工作浓度范围为 7.2 x 10(-8)-1.0 x 10(-1) M。当 pH 值在 2.5-6.8 之间时,电极的电位读数更稳定,响应时间快,为 14 s。该传感器在部分非水介质中(丙酮、甲醇或乙醇的体积含量高达 40%)的性能令人满意,可使用 7-9 个月。汞(Hg(2+))离子的匹配电位法和固定干扰法表明,该传感器具有良好的选择性。该传感器可成功用于不同样品中汞的测定。

相似文献

10
Comparative studies of neodymium (III)-selective PVC membrane sensors.钕(III)选择性PVC膜传感器的比较研究。
Anal Chim Acta. 2009 Aug 4;647(1):66-71. doi: 10.1016/j.aca.2009.05.031. Epub 2009 May 25.

引用本文的文献

1
Metal Cation Detection in Drinking Water.饮用水中的金属阳离子检测。
Sensors (Basel). 2019 Nov 23;19(23):5134. doi: 10.3390/s19235134.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验