Suppr超能文献

开发一种非竞争噬菌体抗免疫复合物测定法,用于测定溴化二苯醚 47。

Development of a noncompetitive phage anti-immunocomplex assay for brominated diphenyl ether 47.

机构信息

Department of Entomology and UCD Cancer Center, University of California, Davis, CA 95616, USA.

出版信息

Anal Biochem. 2010 Jun 1;401(1):38-46. doi: 10.1016/j.ab.2010.01.040. Epub 2010 Feb 10.

Abstract

We present a new application of the noncompetitive phage anti-immunocomplex assay (PHAIA) by converting an existing competitive assay to a versatile noncompetitive sandwich-type format using immunocomplex binding phage-borne peptides to detect the brominated flame retardant, brominated diphenyl ether 47 (BDE 47). Three phage-displayed 9-mer disulfide-constrained peptides that recognize the BDE 47-polyclonal antibody immunocomplex were isolated. The resulting PHAIAs showed variable sensitivities, and the most sensitive peptide had a dose-response curve with an SC(50) (concentration of analyte producing 50% saturation of the signal) of 0.7ng/ml BDE 47 and a linear range of 0.3-2ng/ml, which was nearly identical to the best heterologous competitive format (IC(50) of 1.8ng/ml, linear range of 0.4-8.5/ml). However, the PHAIA was 1400-fold better than homologous competitive assay. The validation of the PHAIA with extracts of house furniture foam as well as human and calf sera spiked with BDE 47 showed overall recovery of 80-113%. The PHAIA was adapted to a dipstick format (limit of detection of 3.0ng/ml), and a blind test with six random extracts of local house furniture foams showed that the results of the PHAIA and dipstick assay were consistent, giving the same positive and negative detection.

摘要

我们提出了非竞争噬菌体抗免疫复合物检测(PHAIA)的新应用,通过将现有的竞争检测转换为通用的非竞争夹心型格式,使用免疫复合物结合噬菌体携带的肽来检测溴化阻燃剂,四溴双酚 A(BDE 47)。分离出了三种噬菌体展示的 9 肽二硫键约束肽,它们能识别 BDE 47-多克隆抗体免疫复合物。所得的 PHAIA 表现出不同的灵敏度,最敏感的肽的剂量反应曲线的 SC(50)(分析物浓度产生 50%信号饱和的浓度)为 0.7ng/ml BDE 47,线性范围为 0.3-2ng/ml,与最佳异源竞争格式(IC(50)为 1.8ng/ml,线性范围为 0.4-8.5/ml)几乎相同。然而,PHAIA 比同源竞争测定法灵敏 1400 倍。用房屋家具泡沫的提取物以及用 BDE 47 标记的人血清和牛血清对 PHAIA 的验证表明,总体回收率为 80-113%。PHAIA 被改编为纸条格式(检测限为 3.0ng/ml),用当地房屋家具泡沫的六个随机提取物进行的盲测表明,PHAIA 和纸条检测的结果是一致的,都给出了相同的阳性和阴性检测。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/9f2a/2861364/fa4d8520def9/nihms195951f1.jpg

相似文献

引用本文的文献

2
Aptamer-Phage Reporters for Ultrasensitive Lateral Flow Assays.用于超灵敏侧向流动分析的适配体-噬菌体报告分子
Anal Chem. 2015 Dec 1;87(23):11660-5. doi: 10.1021/acs.analchem.5b00702. Epub 2015 Nov 11.
7
Virus outbreaks in chemical and biological sensors.化学和生物传感器中的病毒爆发。
Sensors (Basel). 2014 Jul 25;14(8):13592-612. doi: 10.3390/s140813592.

本文引用的文献

3
Flame retardants in the atmosphere near the Great Lakes.五大湖附近大气中的阻燃剂。
Environ Sci Technol. 2008 Jul 1;42(13):4745-51. doi: 10.1021/es800313z.

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。