Hellenic Ophthalmosurgical, Athens, Greece.
Cornea. 2010 Apr;29(4):456-8. doi: 10.1097/ICO.0b013e3181b46bc2.
To report the case of a patient who underwent Descemet stripping automated endothelial keratoplasty complicated by corneal graft detachment without corneal edema.
Case report.
A 60-year-old man with bilateral decompensated endothelium 10 years after cataract extraction and anterior chamber intraocular lens implantation underwent combined anterior chamber intraocular lens explantation with iris-sutured posterior chamber intraocular lens implantation and Descemet stripping automated endothelial keratoplasty on the right eye. On the second postoperative day, the corneal graft was attached. Two weeks postoperatively, slit lamp examination revealed a double anterior chamber resulting from corneal graft detachment. The corneal graft was reattached by repositioning and injecting air. One week later, the corneal graft had detached again, creating a double anterior chamber. No corneal edema was present. Nine months postoperatively, the cornea remained clear, although a double anterior chamber was still evident as a result of the detached corneal graft.
Despite post-Descemet stripping automated endothelial keratoplasty corneal graft detachment, the cornea remained without edema.
报告 1 例接受撕囊自动化角膜内皮移植术(Descemet stripping automated endothelial keratoplasty,DSEA)后发生角膜移植片脱离但无角膜水肿的患者。
病例报告。
1 例 60 岁男性,10 年前因白内障摘除和前房人工晶状体植入术后出现双侧失代偿内皮,右眼行联合前房人工晶状体取出术、虹膜缝线固定的后房人工晶状体植入术和 DSEA。术后第 2 天,角膜移植片附着。术后 2 周,裂隙灯检查发现因角膜移植片脱离导致的双前房。通过重新定位和注入空气使角膜移植片重新附着。1 周后,角膜移植片再次脱离,形成双前房。无角膜水肿。术后 9 个月,角膜仍保持透明,尽管由于角膜移植片脱离,仍存在双前房。