OBJECTIVES

In this study, we evaluate the diagnostic utility of a hybrid γ-camera-computer tomography (SPECT-CT) indium-111 (111-In)-capromab pendetide scan in detecting seminal vesicle invasion (SVI) in select patients evaluated for primary surgical treatment of prostate cancer (CaP).

METHODS AND MATERIALS

We retrospectively analyzed a prospective database of patients who underwent preoperative SPECT-CT imaging with 111-In-capromab-pendetide as part of a staging evaluation who were subsequently treated with radical surgery in our center. Only patients with clinically localized disease were included. We calculated diagnostic properties of the hybrid scan in detecting SVI compared with final pathology. Regression analyses were performed, including scan and preoperative variables to predict SVI.

RESULTS

We retrieved 50 medical records matching our criteria. Median patient age was 61 years (range 45-74). Most patients had a clinical T1c CaP and biopsy Gleason score of 7 or higher. On final pathology, SVI was found in 12 (24%) specimens and radiotracer signal in the seminal vesicle region was reported in 15 (30%) imaging studies. Hybrid SPECT-CT imaging had a sensitivity of 25%, specificity of 61.9%, positive and negative predictive values of 20% and 74.3%, respectively, for detecting SVI. SPECT-CT results did not contribute significantly to SVI prediction on univariate (P = 0.627) or multivariate (P = 0.754) analyses.

CONCLUSIONS

SPECT-CT imaging with 111-In-capromab-pendetide is not reliable in detecting or excluding SVI in this select cohort. High rates of positive radiotracer signals from healthy seminal vesicles raise concerns regarding pharmacologic properties of this radiotracer molecule.

摘要

目的

本研究评估了放射性核素 111 铟(111-In)标记的单克隆抗体 Capromab pendetide 单光子发射计算机断层扫描/计算机断层扫描(SPECT-CT)在选择接受前列腺癌(CaP)根治性手术治疗的患者中检测精囊侵犯(SVI)的诊断价值。

方法与材料

我们对接受 111-In-capromab-pendetide 术前 SPECT-CT 成像作为分期评估一部分且随后在我们中心接受根治性手术治疗的患者前瞻性数据库进行了回顾性分析。仅纳入临床局限性疾病患者。我们计算了混合扫描在检测 SVI 方面与最终病理学的诊断特性。进行了回归分析,包括扫描和术前变量以预测 SVI。

结果

我们检索到 50 份符合我们标准的病历。中位患者年龄为 61 岁(范围 45-74 岁)。大多数患者患有临床 T1c CaP 和活检 Gleason 评分 7 分或更高。在最终病理中,12 例(24%)标本发现 SVI,15 例(30%)影像学研究报告精囊区域放射性示踪剂信号。混合 SPECT-CT 成像检测 SVI 的敏感性为 25%,特异性为 61.9%,阳性预测值和阴性预测值分别为 20%和 74.3%。单变量(P = 0.627)或多变量(P = 0.754)分析均未显示 SPECT-CT 结果对 SVI 预测有显著贡献。

结论

在这个选择的队列中,放射性核素 111-In 标记的单克隆抗体 Capromab pendetide SPECT-CT 成像不能可靠地检测或排除 SVI。来自健康精囊的高放射性示踪剂信号率引起了对该放射性示踪剂分子药理学特性的关注。