Suppr超能文献

佩戴硅橡胶隐形眼镜的兔子过夜闭眼后出现角膜水肿。

Corneal edema after overnight lid closure of rabbits wearing silicone rubber contact lenses.

作者信息

Koch J M, Refojo M F, Leong F L

机构信息

Eye Research Institute, Harvard Medical School, Boston, MA 02114.

出版信息

Cornea. 1991 Mar;10(2):123-6. doi: 10.1097/00003226-199103000-00006.

Abstract

Elastofilcon A silcone rubber contact lenses induce less corneal swelling than no lens wear during sleep, and increasing the central thickness and volume of the lens does not influence its overnight performance. We sought to elucidate whether a silicone rubber lens can promote the distribution of atmospheric O2 on the cornea through a small interpalpebral opening under closed-eye conditions. Three groups of rabbit eyes comprised 12 eyes wearing Silflex (Dk 79.8 barrer) lenses, 12 with elastofilcon A (Dk 340 barrer) lenses, and 12 without lenses. All eyes were surgically closed overnight; six eyes in each group had a complete lid closure and six eyes had a partial tarsorrhaphy that left a small, central gap approximately 3 mm in length. When the lids were opened the next morning, the partially closed elastofilcon A eyes showed less corneal swelling (6.2 +/- 1.4%) than the partially closed no-lens eyes did (9.6 +/- 1.3%) (p less than 0.01), whereas the partially closed Silflex eyes were significantly more swollen (12.8 +/- 2.1%) (p = 0.01) than the other two partially closed groups were. The completely closed eyes showed no significant difference in corneal swelling among the groups. These results indicate that small lid gaps during sleep may lead to less corneal swelling when elastofilcon A lenses are used than with no lenses.

摘要

与睡眠时不戴隐形眼镜相比,Elastofilcon A硅橡胶隐形眼镜引起的角膜肿胀更少,增加镜片的中心厚度和体积并不影响其过夜佩戴效果。我们试图阐明在闭眼条件下,硅橡胶镜片是否能通过睑裂小开口促进大气中的氧气在角膜上的分布。三组兔眼,每组12只,分别为佩戴Silflex(Dk值79.8巴)镜片的兔眼、佩戴Elastofilcon A(Dk值340巴)镜片的兔眼和不戴镜片的兔眼。所有眼睛均通过手术在夜间闭合;每组中有6只眼睛完全闭合眼睑,6只眼睛进行部分睑缘缝合,留下一个约3毫米长的中央小间隙。第二天早上睁开眼睑时,部分闭合的Elastofilcon A组兔眼角膜肿胀程度(6.2±1.4%)低于部分闭合的无镜片组兔眼(9.6±1.3%)(p<0.01),而部分闭合的Silflex组兔眼角膜肿胀程度(12.8±2.1%)明显高于其他两组部分闭合的兔眼(p=0.01)。完全闭合眼睑的兔眼在各实验组之间角膜肿胀无显著差异。这些结果表明,睡眠时睑裂小间隙使用Elastofilcon A镜片比不使用镜片可能导致角膜肿胀程度更低。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验