Moezzi Amir M, Fonn Desmond, Varikooty Jalaiah, Simpson Trefford L
Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.
Centre for Contact Lens Research, School of Optometry and Vision Science, University of Waterloo, Waterloo, Ontario, Canada.
J Optom. 2015 Jan-Mar;8(1):19-26. doi: 10.1016/j.optom.2014.03.002. Epub 2014 Apr 24.
To compare central corneal swelling after eight hours of sleep in eyes wearing four different silicone hydrogel lenses with three different powers.
Twenty-nine neophyte subjects wore lotrafilcon A (Dk, 140), balafilcon A (Dk, 91), galyfilcon A (Dk, 60) and senofilcon A (Dk, 103) lenses in powers -3.00, -10.00 and +6.00 D on separate nights, in random order, and on one eye only. The contra-lateral eye (no lens) served as the control. Central corneal thickness was measured using a digital optical pachometer before lens insertion and immediately after lens removal on waking.
For the +6.00 D and -10.00 D, lotrafilcon A induced the least swelling and galyfilcon A the most. The +6.00 D power, averaged across lens materials, induced significantly greater central swelling than the -10.00 and -3.00 D (Re-ANOVA, p<0.001), (7.7±2.9% vs. 6.8±2.8% and 6.5±2.5% respectively) but there was no difference between -10.00 and -3.00 D. Averaged for power, lotrafilcon A induced the least (6.2±2.8%) and galyfilcon A the most (7.6±3.0%) swelling at the center (Re-ANOVA, p<0.001). Central corneal swelling with +6.00 D was significantly greater than -10.00 D lens power despite similar levels of average lens transmissibility of these two lens powers.
The differences in corneal swelling of the lens wearing eyes are consistent with the differences in oxygen transmission of the silicone hydrogel lenses. In silicone hydrogel lenses central corneal swelling is mainly driven by central lens oxygen transmissibility.
比较佩戴三种不同屈光度的四种不同硅水凝胶镜片睡眠八小时后中央角膜肿胀情况。
29名初戴者在不同夜晚分别单眼随机佩戴屈光度为-3.00D、-10.00D和+6.00D的lotrafilcon A(Dk值为140)、balafilcon A(Dk值为91)、galyfilcon A(Dk值为60)和senofilcon A(Dk值为103)镜片。对侧眼(不戴镜片)作为对照。在插入镜片前及醒来摘下镜片后立即使用数字光学厚度仪测量中央角膜厚度。
对于+6.00D和-10.00D镜片,lotrafilcon A引起的肿胀最小,galyfilcon A引起的肿胀最大。综合各镜片材料来看,+6.00D屈光度引起的中央肿胀明显大于-10.00D和-3.00D(重复方差分析,p<0.001),分别为(7.7±2.9% vs. 6.8±2.8%和6.5±2.5%),但-10.00D和-3.00D之间无差异。按屈光度平均计算,lotrafilcon A在中央引起的肿胀最小(6.2±2.8%),galyfilcon A最大(7.6±3.0%)(重复方差分析,p<0.001)。尽管这两种屈光度镜片的平均透氧率水平相似,但+6.00D镜片引起的中央角膜肿胀明显大于-10.00D镜片。
戴镜眼的角膜肿胀差异与硅水凝胶镜片的透氧性差异一致。在硅水凝胶镜片中,中央角膜肿胀主要由镜片中央透氧性驱动。