Yoon Woong, Lee Min Young, Ryu Jung Min, Moon Yong Ju, Lee Sang Hun, Park Jae Hong, Yun Seung Pil, Jang Min Woo, Park Sung Su, Han Ho Jae
Department of Radiology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Korea.
J Vet Sci. 2010 Mar;11(1):9-13. doi: 10.4142/jvs.2010.11.1.9.
Multidetector row computed tomography (MDCT) provides anatomical information about the kidney and other internal organs. Presently, the suitability of 64-channel MDCT to assess the kidney of healthy micropigs was evaluated. Morphological evaluations of the kidney and the major renal vessels of six healthy micropigs were carried out using MDCT, recording kidney volume and the diameter and length of renal arteries and veins. The mean diameters and lengths of the renal artery were 0.44 +/- 0.05 and 4.51 +/- 0.55 cm on the right side and 0.46 +/- 0.06 and 3.36 +/- 0.27 cm on the left side, respectively. The mean diameters and lengths of the renal vein were 1.44 +/- 0.52 and 4.22 +/- 1.29 cm on the right side and 1.38 +/- 0.17 and 5.15 +/- 0.87 cm on the left side, respectively. The mean volume of the right kidney was 79.3 +/- 14.5 mL and of the left kidney was 78.0 +/- 13.9 mL. The data presented in this study suggest that the MDCT offers a noninvasive, rapid, and accurate method for the evaluation of the renal anatomy in living kidney donors. It also provides sufficient information about extra-renal anatomy important for donor surgery and determination of organ suitability.
多排螺旋计算机断层扫描(MDCT)可提供有关肾脏及其他内部器官的解剖信息。目前,对64排MDCT评估健康小型猪肾脏的适用性进行了评估。使用MDCT对6只健康小型猪的肾脏及主要肾血管进行形态学评估,记录肾脏体积以及肾动脉和肾静脉的直径与长度。右侧肾动脉的平均直径和长度分别为0.44±0.05厘米和4.51±0.55厘米,左侧分别为0.46±0.06厘米和3.36±0.27厘米。右侧肾静脉的平均直径和长度分别为1.44±0.52厘米和4.22±1.29厘米,左侧分别为1.38±0.17厘米和5.15±0.87厘米。右肾平均体积为79.3±14.5毫升,左肾为78.0±13.9毫升。本研究呈现的数据表明,MDCT为评估活体肾供体的肾脏解剖结构提供了一种非侵入性、快速且准确的方法。它还提供了有关肾外解剖结构的充分信息,这对供体手术及器官适用性的判定很重要。