Transesophageal echocardiographic monitoring during coronary artery bypass surgery.

作者信息

Rosenthal A, Kawasuji M, Takemura H, Sawa S, Iwa T

机构信息

Department of Surgery (I), Kanazawa University School of Medicine, Japan.

出版信息

Jpn Circ J. 1991 Feb;55(2):109-16. doi: 10.1253/jcj.55.109.

DOI:10.1253/jcj.55.109
PMID:2020080
Abstract

To demonstrate serial changes of left ventricular (LV) function during coronary artery bypass grafting surgery, transesophageal echocardiography (TEE) was used in 17 patients. The cross-sectional image of the left ventricle at the level of the papillary muscles was monitored, and was analyzed immediately in the operating room using a computer-assisted cine-memory function. Global LV function was evaluated by measuring LV end-diastolic and end-systolic area and computing the fractional area change (FAC). Segmental wall motion abnormalities (SWMA) were graded according to a scoring system. During the operative procedure before sternal closure, 5 patients showed SWMA with a simultaneous decrease in FAC to under 40%, and 9 patients showed SWMA without FAC depression. Two-thirds of new SWMA improved after myocardial revascularization. All 17 patients showed a change of interventricular septal movement at the end of the operation. FAC improved from a mean value (+/- SD) after intubation of 47.6 +/- 10.7% to a mean value after revascularization of 58.5 +/- 13.0% (p less than 0.05) and to a mean value at the end of the operation of 55.9 +/- 12.2% (p less than 0.05). Thus: 1) global and regional LV function improved immediately after myocardial revascularization with administration of inotropic agents; 2) a significant change of interventricular septal movement occurred after sternal closure; and 3) intraoperative TEE monitoring is a safe, simple, and effective method for evaluating LV global and regional function.

摘要

相似文献

1
Transesophageal echocardiographic monitoring during coronary artery bypass surgery.
Jpn Circ J. 1991 Feb;55(2):109-16. doi: 10.1253/jcj.55.109.
2
[Transesophageal echocardiography during coronary bypass surgery].
Nihon Kyobu Geka Gakkai Zasshi. 1991 Nov;39(11):2017-22.
3
[Transesophageal echocardiography during coronary bypass surgery].
Kyobu Geka. 1990 Jan;43(1):31-5.
4
The effects of nitrous oxide on left ventricular systolic and diastolic performance before and after cardiopulmonary bypass: evaluation by computer-assisted two-dimensional and Doppler echocardiography in patients undergoing coronary artery surgery.一氧化二氮对体外循环前后左心室收缩和舒张功能的影响:通过计算机辅助二维和多普勒超声心动图对冠状动脉手术患者进行评估
Anesth Analg. 1995 Aug;81(2):243-8. doi: 10.1097/00000539-199508000-00006.
5
The feasibility of speckle tracking for intraoperative assessment of regional myocardial function by transesophageal echocardiography.经食管超声心动图斑点追踪技术用于术中评估局部心肌功能的可行性。
J Cardiothorac Vasc Anesth. 2009 Aug;23(4):462-7. doi: 10.1053/j.jvca.2008.12.002. Epub 2009 Feb 13.
6
Echocardiographic and hemodynamic indexes of left ventricular preload in patients with normal and abnormal ventricular function.心室功能正常和异常患者左心室前负荷的超声心动图和血流动力学指标。
Anesthesiology. 1994 Aug;81(2):376-87. doi: 10.1097/00000542-199408000-00016.
7
Echocardiographic findings in minimally invasive coronary artery bypass grafting: The role of intrathoracic CO2 - insufflation and single lung ventilation.微创冠状动脉旁路移植术中的超声心动图表现:胸腔内二氧化碳充气和单肺通气的作用
Heart Surg Forum. 2002;5 Suppl 4:S398-419.
8
Influence of coronary artery bypass surgery on regional left ventricular wall motion: an intraoperative two-dimensional transesophageal echocardiographic study.
J Cardiothorac Anesth. 1987 Aug;1(4):276-83. doi: 10.1016/s0888-6296(87)80037-6.
9
Decreased right ventricular function after coronary artery bypass grafting.冠状动脉旁路移植术后右心室功能减退。
Tex Heart Inst J. 2008;35(3):250-5.
10
Evaluation of intraoperative transesophageal two-dimensional echocardiography.术中经食管二维超声心动图评估
Anesthesiology. 1987 Jan;66(1):64-8. doi: 10.1097/00000542-198701000-00012.