Abstract

The rapid injection into the coronary circulation of solutions containing microbubbles produces an ultrasonic contrast effect in the myocardium. The time-intensity curves generated by sequential videodensitometric analysis of contrast intensity, which is corrected for myocardial background intensity, resembles the curves used in indicator dilution techniques. Studies done in vitro have demonstrated a direct relation between contrast intensity and amount of microbubbles. In animal studies, measurements derived from these curves correlated with changes in myocardial blood flow assessed by microspheres but with varying controversial results. Differences between investigators in technique of injection and size of microbubbles injected are among the list of factors that will alter the time-intensity curve and explain some of the differences in results between investigators. Several factors limit the application of myocardial contrast echocardiography (MCE) to the quantitation of myocardial blood flow. Nevertheless, the results from multiple investigations suggest that the technique is sensitive to changes in perfusion and may be applicable to the evaluation of regional coronary reserve and assessment of the results of revascularization procedures. Peak intensity and area under the time-intensity curve have provided consistent results between investigators; therefore, these measurements have been used to assess regional coronary reserve in experimental studies and patients with coronary artery disease. Although the results are encouraging, they cannot distinguish well between normal and mild impairments in coronary reserve and are subject to larger reproducibility errors.(ABSTRACT TRUNCATED AT 250 WORDS)

摘要

将含有微泡的溶液快速注入冠状动脉循环会在心肌中产生超声造影效果。通过对造影剂强度进行连续视频密度分析生成的时间-强度曲线(该强度已针对心肌背景强度进行校正)类似于指示剂稀释技术中使用的曲线。体外研究表明造影剂强度与微泡数量之间存在直接关系。在动物研究中,从这些曲线得出的测量值与通过微球评估的心肌血流变化相关,但结果存在不同程度的争议。研究人员在注射技术和注入微泡大小方面的差异是改变时间-强度曲线并解释研究人员之间结果差异的部分因素。有几个因素限制了心肌对比超声心动图(MCE)在心肌血流定量方面的应用。尽管如此,多项研究结果表明该技术对灌注变化敏感,可能适用于评估局部冠状动脉储备和血管重建手术效果。研究人员之间,时间-强度曲线的峰值强度和曲线下面积得出了一致的结果;因此,这些测量值已用于实验研究和冠心病患者中评估局部冠状动脉储备。尽管结果令人鼓舞,但它们无法很好地区分冠状动脉储备正常和轻度受损情况,并且存在较大的可重复性误差。(摘要截断于250字)

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验