Suppr超能文献

采用顶空固相微萃取-气相色谱-质谱法研究香味玩具中散发的芳香过敏原。

Investigations on the emission of fragrance allergens from scented toys by means of headspace solid-phase microextraction gas chromatography-mass spectrometry.

机构信息

Federal Institute for Risk Assessment, Department of Product Safety, Thielallee 88-92, 14195 Berlin, Germany.

出版信息

J Chromatogr A. 2010 Apr 30;1217(18):3136-43. doi: 10.1016/j.chroma.2010.02.072. Epub 2010 Mar 4.

Abstract

In the revised European toy safety directive 2009/48/EC the application of fragrance allergens in children's toys is restricted. The focus of the present work lies on the instrumental analytics of 13 banned fragrance allergens, as well as on 11 fragrance allergens that require declaration when concentrations surpass 100 microg per gram material. Applying a mixture of ethyl acetate and toluene solid/liquid extraction was performed prior to quantitative analysis of mass contents of fragrances in scented toys. In addition, an easy-to-perform method for the determination of emitted fragrances at 23 degrees C (handling conditions) or at 40 degrees C (worst case scenario) has been worked out to allow for the evaluation of potential risks originating from inhalation of these compounds during handling of or playing with toys. For this purpose a headspace solid-phase microextraction (HS-SPME) technique was developed and coupled to subsequent gas chromatography-mass spectrometry (GC-MS) analysis. Fragrance allergens were adsorbed (extracted) from the gas phase onto an 85 microm polyacrylate fiber while incubating pieces of the scented toys in sealed headspace vials at 23 degrees C and 40 degrees C. Quantification of compounds was performed via external calibration. The newly developed headspace method was subsequently applied to five perfumed toys. As expected, the emission of fragrance allergens from scented toys depends on the temperature and on the content of fragrance allergens present in those samples. In particular at conditions mimicking worst case (40 degrees C), fragrance allergens in toys may pose a risk to children since considerable amounts of compound might be absorbed by lung tissue via breathing of contaminated air.

摘要

在修订后的欧洲玩具安全指令 2009/48/EC 中,限制了儿童玩具中使用香料过敏原。本工作的重点在于对 13 种被禁止的香料过敏原以及 11 种当浓度超过 100 微克/克材料时需要申报的香料过敏原进行仪器分析。在对有香味的玩具中的香料进行定量分析之前,应用乙酸乙酯和甲苯的混合物进行固/液萃取。此外,还制定了一种易于执行的方法,用于在 23°C(处理条件)或 40°C(最坏情况)下测定释放的香料,以评估在处理或玩耍玩具时吸入这些化合物所带来的潜在风险。为此,开发了顶空固相微萃取(HS-SPME)技术,并与随后的气相色谱-质谱(GC-MS)分析相结合。在 23°C 和 40°C 的密封顶空瓶中孵育有香味的玩具片时,将气相中的香料过敏原吸附(提取)到 85 微米的聚丙烯酸酯纤维上。通过外部校准进行化合物的定量。新开发的顶空方法随后应用于五个有香味的玩具。正如预期的那样,有香味的玩具中香料过敏原的排放取决于温度和这些样品中存在的香料过敏原的含量。特别是在模拟最坏情况(40°C)的条件下,玩具中的香料过敏原可能对儿童构成风险,因为通过呼吸污染的空气,大量的化合物可能会被肺部组织吸收。

相似文献

2
Sorbent trapping solid-phase microextraction of fragrance allergens in indoor air.
J Chromatogr A. 2010 Aug 13;1217(33):5307-16. doi: 10.1016/j.chroma.2010.06.036. Epub 2010 Jun 19.
5
Development of a method based on sorbent trapping followed by solid-phase microextraction for the determination of synthetic musks in indoor air.
J Chromatogr A. 2009 Apr 3;1216(14):2805-15. doi: 10.1016/j.chroma.2008.09.062. Epub 2008 Sep 24.
6
Rapid and green determination of 58 fragrance allergens in plush toys.
J Sep Sci. 2018 Feb;41(3):657-668. doi: 10.1002/jssc.201700556. Epub 2017 Dec 14.
8
Solid-phase microextraction gas chromatography-mass spectrometry determination of fragrance allergens in baby bathwater.
Anal Bioanal Chem. 2009 Jul;394(5):1399-411. doi: 10.1007/s00216-009-2829-2. Epub 2009 May 21.
10
Determination of fragrance allergens in cosmetics by size-exclusion chromatography followed by gas chromatography-mass spectrometry.
J Chromatogr A. 2006 Nov 3;1132(1-2):109-16. doi: 10.1016/j.chroma.2006.07.055. Epub 2006 Sep 1.