Suppr超能文献

实验室间测量比较以确定渐变折射率光纤的衰减和带宽。

Interlaboratory measurement comparison to determine the attenuation and bandwidth of graded-index optical fibers.

作者信息

Franzen D L, Day G W, Danielson B L, Chamberlain G E, Kim E M

出版信息

Appl Opt. 1981 Jul 15;20(14):2412-9. doi: 10.1364/AO.20.002412.

Abstract

An interlaboratory measurement comparison was conducted by the National Bureau of Standards in cooperation with the Electronic Industries Association. Participants included NBS and nine optical fiber and cable manufacturers. Four graded-index fibers having lengths of 2, 2, 2, and 0.9 km were used. Measurements of attenuation at 850 nm, using both beam optics and mode filter approaches to achieve a restricted launch, gave one standard deviation spreads of 0.24, 0.12, 0.12, and 0.43 dB/km for an overall average of 0.23 dB/km. Best measurement agreement was obtained for a fiber having little differential mode attenuation. Measurements of -3-dB bandwidth from time domain acquired data at 90 nm gave an average one standard deviation spread of 12% with poorer agreement on the higher frequency portion of the frequency response.

摘要

国家标准局与电子工业协会合作进行了一项实验室间测量比较。参与者包括国家标准局以及九家光纤和光缆制造商。使用了四根长度分别为2千米、2千米、2千米和0.9千米的渐变折射率光纤。在850纳米波长下,采用光束光学和模式滤波器方法实现受限发射来测量衰减,得到的标准偏差分别为0.24、0.12、0.12和0.43分贝/千米,总体平均值为0.23分贝/千米。对于具有较小差分模式衰减的光纤,测量一致性最佳。从时域采集的数据中测量90纳米处的-3分贝带宽,得到的平均标准偏差扩展为12%,在频率响应的高频部分一致性较差。