使用 Lock-It 系统的 Padlock-G 夹对猪标本进行经自然腔道内镜手术胃造口闭合。

Natural orifice transluminal endoscopic surgery gastrotomy closure in porcine explants with the Padlock-G clip using the Lock-It system.

机构信息

Department of Surgery, Baystate Medical Center, Tufts University School of Medicine, Springfield, Massachusetts 01199, USA.

出版信息

Endoscopy. 2010 Apr;42(4):306-10. doi: 10.1055/s-0029-1243950. Epub 2010 Mar 30.

Abstract

BACKGROUND AND STUDY AIMS

The success of transgastric surgery depends on reliable, secure closure of the gastrotomy. Few tests of the integrity of these closures have been published. This study aimed to determine whether a gastrotomy suitable for a NOTES procedure can be closed safely and effectively from within the stomach using a novel endoscopically placed device, the Padlock-G with the Lock-It delivery system.

METHODS

In a series of eight consecutive porcine gastric explants gastrotomy was performed in an ex vivo animal laboratory, the gastrotomy being closed with the Padlock-G followed by burst pressure testing after completion of the procedure. Gastrotomies were made in porcine explants. T-tags were placed on either side of the gastrotomy, and, with the T-tags pulled into an endoscopic cap, the Padlock-G was deployed. Gastric transmural pressure gradients at bursting of these closures were measured during insufflation of the explanted stomachs with a high-pressure insufflator.

RESULTS

The mean burst pressure of the gastrotomy closures was 68.0 mm Hg (range: 45 - 107 mm Hg). All of the stomachs ultimately ruptured at the closure sites, with the exception of the stomach that ruptured at the highest value (107 mm Hg), which ruptured at a site approximately 5 cm away from the closure site. All of the closures were accomplished in 30 minutes or less.

CONCLUSIONS

The Padlock-G clip provides a secure gastric closure for natural-orifice surgery.

摘要

背景与研究目的

经胃外科手术的成功取决于胃造口术可靠且安全的闭合。目前仅有少数关于这些闭合完整性的测试被报道。本研究旨在确定一种新型内镜下放置的装置 Padlock-G 与 Lock-It 输送系统是否可安全有效地从胃内闭合NOTES 手术适用的胃造口术。

方法

在一系列连续的 8 例猪胃离体实验中,在体外动物实验室进行胃造口术,用 Padlock-G 闭合胃造口术,然后在完成手术程序后进行爆裂压力测试。在猪离体样本中进行胃造口术。在胃造口术的两侧放置 T 型夹,然后将 T 型夹拉入内镜帽中,部署 Padlock-G。在通过高压注气装置向离体胃充气时测量这些闭合处的胃壁全层压力梯度。

结果

胃造口术闭合的平均爆裂压力为 68.0mmHg(范围:45-107mmHg)。所有胃最终均在闭合部位破裂,除了在最高压力(107mmHg)下破裂的胃,其在距闭合部位约 5cm 的部位破裂。所有的闭合操作都在 30 分钟或更短时间内完成。

结论

Padlock-G 夹可安全有效地闭合经自然腔道的外科手术中的胃造口术。