睫状沟直径与前房直径和角膜直径的关系。

Relationship between ciliary sulcus diameter and anterior chamber diameter and corneal diameter.

机构信息

Department of Orthoptics and Visual Science, Kitasato University School of Allied Health Sciences, Sagamihara, Japan.

出版信息

J Cataract Refract Surg. 2010 Apr;36(4):617-24. doi: 10.1016/j.jcrs.2009.11.017.

Abstract

PURPOSE

To evaluate the relationship between the horizontal ciliary sulcus diameter and anterior chamber diameter measured by 35 MHz ultrasound biomicroscopy (UBM) and the horizontal corneal diameter (white to white [WTW]) measured by scanning-slit topography and to assess the repeatability (intraexaminer difference) of the 2 methods.

SETTING

Department of Orthoptics and Visual Science, Kitasato University School, Sagamihara, Japan.

METHODS

The repeatability and agreement of UBM and scanning-slit topography were assessed using the intraclass correlation (ICC) and the Bland and Altman method (ie, mean difference and 95% limits of agreement [LoA]).

RESULTS

Thirty-one normal eyes of 31 subjects (mean age 22.6 years +/- 4.8 [SD]) were evaluated. The mean differences between the repeated measurements were as follows: ciliary sulcus diameter, -0.05 mm (95% LoA, -0.38 to 0.28 mm); anterior chamber diameter, 0.02 mm (95% LoA, -0.42 to 0.45 mm); and WTW diameter, -0.02 mm (95% LoA, -0.18 to 0.13 mm). The agreement between ciliary sulcus diameter and WTW diameter was poor (ICC, 0.679). The mean difference was 0.41 mm (95% LoA, -0.46 to 1.28 mm). The agreement between the ciliary sulcus diameter and anterior chamber diameter was high (ICC, 0.918). The mean difference was 0.13 mm (95% LoA, -0.41 to 0.67 mm).

CONCLUSION

Results suggest that direct measurement of the ciliary sulcus by UBM would reduce the percentage of complications related to intraocular lens sizing over the percentage when sizing is based on WTW diameter.

摘要

目的

评估 35MHz 超声生物显微镜(UBM)测量的水平睫状沟直径和前房直径与扫描裂隙地形图测量的水平角膜直径(白对白 [WTW])之间的关系,并评估这两种方法的重复性(观察者内差异)。

地点

日本相模原市北里大学眼科学院视光学系。

方法

使用组内相关系数(ICC)和 Bland 和 Altman 方法(即平均差值和 95%一致性界限 [LoA])评估 UBM 和扫描裂隙地形图的重复性和一致性。

结果

对 31 名受试者的 31 只正常眼(平均年龄 22.6 岁 +/- 4.8 [SD])进行了评估。重复测量的平均差值如下:睫状沟直径为-0.05mm(95%LoA,-0.38 至 0.28mm);前房直径为 0.02mm(95%LoA,-0.42 至 0.45mm);WTW 直径为-0.02mm(95%LoA,-0.18 至 0.13mm)。睫状沟直径与 WTW 直径之间的一致性较差(ICC,0.679)。平均差值为 0.41mm(95%LoA,-0.46 至 1.28mm)。睫状沟直径与前房直径之间的一致性较高(ICC,0.918)。平均差值为 0.13mm(95%LoA,-0.41 至 0.67mm)。

结论

结果表明,与基于 WTW 直径的晶状体尺寸相比,UBM 直接测量睫状沟可以降低与晶状体尺寸相关的并发症的百分比。