Suppr超能文献

不同方法测量的角膜白到白直径的每日变化

Daily Variations of Corneal White-to-White Diameter Measured with Different Methods.

作者信息

Bandlitz Stefan, Nakhoul Makram, Kotliar Konstantin

机构信息

Höhere Fachschule für Augenoptik Köln (HFAK), Cologne School of Optometry, Cologne, Germany.

School of Life and Health Sciences, Aston University, Birmingham, UK.

出版信息

Clin Optom (Auckl). 2022 Sep 20;14:173-181. doi: 10.2147/OPTO.S360651. eCollection 2022.

Abstract

PURPOSE

A precise determination of the corneal diameter is essential for the diagnosis of various ocular diseases, cataract and refractive surgery as well as for the selection and fitting of contact lenses. The aim of this study was to investigate the agreement between two automatic and one manual method for corneal diameter determination and to evaluate possible diurnal variations in corneal diameter.

PATIENTS AND METHODS

Horizontal white-to-white corneal diameter of 20 volunteers was measured at three different fixed times of a day with three methods: Scheimpflug method (Pentacam HR, Oculus), placido based topography (Keratograph 5M, Oculus) and manual method using an image analysis software at a slitlamp (BQ900, Haag-Streit).

RESULTS

The two-factorial analysis of variance could not show a significant effect of the different instruments (p = 0.117), the different time points (p = 0.506) and the interaction between instrument and time point (p = 0.182). Very good repeatability (intraclass correlation coefficient ICC, quartile coefficient of dispersion QCD) was found for all three devices. However, manual slitlamp measurements showed a higher QCD than the automatic measurements with the Keratograph 5M and the Pentacam HR at all measurement times.

CONCLUSION

The manual and automated methods used in the study to determine corneal diameter showed good agreement and repeatability. No significant diurnal variations of corneal diameter were observed during the period of time studied.

摘要

目的

精确测定角膜直径对于各种眼科疾病、白内障及屈光手术的诊断以及隐形眼镜的选择和适配至关重要。本研究的目的是调查两种自动方法和一种手动方法在角膜直径测定方面的一致性,并评估角膜直径可能存在的昼夜变化。

患者与方法

使用三种方法在一天中的三个不同固定时间测量20名志愿者的水平白到白角膜直径:Scheimpflug法(Pentacam HR,Oculus)、基于普拉西多盘的地形图法(Keratograph 5M,Oculus)以及使用裂隙灯图像分析软件的手动方法(BQ900,Haag-Streit)。

结果

双因素方差分析未显示不同仪器(p = 0.117)、不同时间点(p = 0.506)以及仪器与时间点之间的交互作用(p = 0.182)有显著影响。所有三种设备均具有非常好的重复性(组内相关系数ICC,四分位数离散系数QCD)。然而,在所有测量时间,手动裂隙灯测量的QCD均高于使用Keratograph 5M和Pentacam HR的自动测量。

结论

本研究中用于测定角膜直径的手动和自动方法显示出良好的一致性和重复性。在所研究的时间段内未观察到角膜直径有显著的昼夜变化。

https://cdn.ncbi.nlm.nih.gov/pmc/blobs/5cbd/9509000/846c65826f90/OPTO-14-173-g0001.jpg

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验