A quick and reproducible electrochemical-based immunosensor technique, using magnetic core/shell particles that are coated with self-assembled multilayer of nanogold, has been developed. Magnetic particles that are structured from Au/Fe(3)O(4) core-shells were prepared and aminated after a reaction between gold and thiourea, and additional multilayered coatings of gold nanoparticles were assembled on the surface of the core/shell particles. The carcinoembryonic antibody (anti-CEA) was immobilized on the modified magnetic particles, which were then attached on the surface of solid paraffin carbon paste electrode (SPCE) by an external magnetic field. This is an assembly of a novel immuno biosensor for carcinoembryonic antigen (CEA). The sensitivity and response features of this immunoassay are significantly affected by the surface area and the biological compatibility of the multilayered nanogold. The linear range for the detection of CEA was from 0.005 to 50 ng mL(-1) and the limit of detection (LOD) was 0.001 ng mL(-1). The LOD is approximately 500 times more sensitive than that of the traditional enzyme-linked immunosorbent assay for CEA detection.
一种快速且可重现的基于电化学的免疫传感器技术,使用涂有自组装纳米金多层的磁性核/壳颗粒,已经被开发出来。金/Fe3O4 核/壳结构的磁性颗粒是通过金和硫脲之间的反应制备和胺化的,并且在核/壳颗粒的表面上组装了额外的多层金纳米颗粒涂层。癌胚抗原(anti-CEA)被固定在修饰的磁性颗粒上,然后通过外部磁场将其附着在固体石蜡碳糊电极(SPCE)的表面上。这是一种新型癌胚抗原(CEA)免疫生物传感器的组装体。该免疫分析的灵敏度和响应特征受到多层纳米金的表面积和生物相容性的显著影响。检测 CEA 的线性范围为 0.005 至 50ng/mL,检测限(LOD)为 0.001ng/mL。LOD 比传统的 CEA 检测酶联免疫吸附测定法敏感约 500 倍。