Suppr超能文献

成人下颌骨正中旁区域牙槽间隙及前庭皮质骨厚度的断层分析。

Tomographic analysis of the interalveolar space and thickness of the vestibular cortical bone in the parasymphyseal region of adult human mandibles.

作者信息

de Souza Fernandes Atson Carlos, de Quadros Uzeda-Gonzalez Sandra, Smith Ricardo Luiz, Alonso Luis Garcia, Gonzalez Fabio Mota, Santos Marcos Vinicius

机构信息

Departamento De Ciências Da Vida (DCV), Universidade do Estado da Bahia (UNEB), Rua Silveira Martins, 2555, Cabula, Salvador, Bahia, CEP 41195001, Brazil.

出版信息

Surg Radiol Anat. 2010 Dec;32(10):951-6. doi: 10.1007/s00276-010-0659-8. Epub 2010 Apr 10.

Abstract

PURPOSE

The aim of this study was to determine by computed tomography (CT) the interalveolar distance on mandible relative to the canine, first and second pre-molar, and the thickness of the cortical bone in the same region.

METHODS

A hundred adult cadaveric dentate human hemi-mandibles were examined. A point (P) above the upper margin of the mental foramen was determined, the height at which monocortical screws are inserted to place miniplate according to the technique to treat mandibular fracture. Then, points A, B and C at the same height as point P, referring to the dental units namely canine, first and second pre-molars were marked to determine the CT cut level to measure cortical bone thickness and the interalveolar distance.

RESULTS

The figures showed no statistically significant difference between the sides. The thickness of the vestibular cortical bone was less than 3.0 mm in 96% of the samples. In 91% of the samples the interalveolar distance between canine, first and second pre-molars was greater than 2 mm, a potentially safe condition to insert 2.0-mm diameter monocortical screws at the study points.

CONCLUSIONS

The individual actual anatomy of the region where screws are to be inserted above the mental foramen is important to perform the technique safely. We believe that the minimal cortical thickness to obtain sufficient screw anchorage should be studied in order to determine the actually safe shortest screw length. It is important to minimize the risk of tooth root damage or nerve injury and the amount of titanium in the human tissues.

摘要

目的

本研究旨在通过计算机断层扫描(CT)确定下颌骨相对于犬齿、第一和第二前磨牙的牙槽间距离,以及同一区域皮质骨的厚度。

方法

检查了100具成年带牙的人类半侧下颌骨尸体。确定颏孔上缘上方的一个点(P),即根据治疗下颌骨骨折的技术插入单皮质螺钉以放置微型钢板的高度。然后,在与点P相同高度处,参照犬齿、第一和第二前磨牙等牙位标记点A、B和C,以确定测量皮质骨厚度和牙槽间距离的CT扫描层面。

结果

数据显示两侧之间无统计学显著差异。96%的样本中前庭皮质骨厚度小于3.0毫米。91%的样本中犬齿、第一和第二前磨牙之间的牙槽间距离大于2毫米,这是在研究点插入直径2.0毫米单皮质螺钉的潜在安全条件。

结论

颏孔上方螺钉插入区域的个体实际解剖结构对于安全实施该技术很重要。我们认为,为了确定实际安全的最短螺钉长度,应研究获得足够螺钉锚固所需的最小皮质厚度。尽量减少牙根损伤或神经损伤的风险以及人体组织中钛的含量很重要。