Fonck R J, Ramsey A T, Yelle R V
Princeton University, Plasma Physics Laboratory, Princeton, New Jersey 08544, USA.
Appl Opt. 1982 Jun 15;21(12):2115-23. doi: 10.1364/AO.21.002115.
A compact vacuum ultraviolet spectrometer system has been developed to provide time-resolved impurity spectra from tokamak plasmas. Two interchangeable aberration-corrected toroidal diffraction gratings with flat focal fields provide simultaneous coverage over the ranges 100-1100 A or 160-1700 A. The detector is an intensified self-scanning photodiode array. Spectral resolution is 2 A with the higher dispersion grating. Minimum readout time for a full spectrum is 20 msec, but up to seven individual spectral lines can be measured with a 1-msec time resolution. The sensitivity of the system is comparable with that of a conventional grazing-incidence monochromator.