Sharma K D, Gopal S V
Appl Opt. 1982 Dec 15;21(24):4439-42. doi: 10.1364/AO.21.004439.
The significance of proper selection of Petzval curvature P in the Cooke triplet design has been investigated. Seven triplet systems at 100 mm, f/5.0 for a 35-mm camera, have been designed for seven different values of P (0.0037-0.0002-0.0049), and their performances are evaluated and compared. It is observed that the performance of the triplet does not vary linearly with the value of P. The triplet designed with a value of P = 0.0043 gives the best performance. Its performance deteriorates rapidly for designs developed with P values lying on either side of this optimum value.