Suppr超能文献

多排 CT 在 Boyd-Griffin Ⅱ型转子间骨折中的应用及其临床相关性研究

Usefulness of multi-detector CT in Boyd-Griffin type 2 intertrochanteric fractures with clinical correlation.

机构信息

Department of Orthopaedic Surgery, St. Paul's Hospital, College of Medicine, The Catholic University of Korea, Jeonnong-dong 620-56, Dongdaemun-ku, Seoul, Korea.

出版信息

Skeletal Radiol. 2010 Jun;39(6):543-9. doi: 10.1007/s00256-009-0795-6. Epub 2009 Sep 8.

Abstract

OBJECTIVE

To investigate the usefulness of multi-detector computed tomography (MDCT) in three-part intertrochanteric fractures of proximal femur.

MATERIALS AND METHODS

Twenty-six patients with Boyd-Griffin type 2 intertrochanteric fractures with MDCT (group 1) and 36 patients of the same type fracture without MDCT (group 2) were compared. Lesser trochanter (LT)/greater trochanter (GT) volume ratio above 0.5 or the volumetric proportion of GT in total volume of proximal femur below 25% was considered an unstable fracture. The fractures were fixed with dynamic compression hip screws (DCS). Additional greater trochanter stabilizing (GTS) plate or bone cement augmentation of the femoral head was performed in unstable fractures. Clinical outcome between the two groups by fixation failure and radiological results was compared.

RESULTS

The volume ratio of the LT/GT was 0.33 (range, 0.13-0.73). The volume of the LT was inversely correlated with that of the GT (p < 0.001). The volume of the GT was significantly correlated with the LT/GT ratio or the head and neck (HN)/GT ratio (p < 0.001). Seven cases were regarded as unstable fractures in group 1. Fixation failures happened in one case in group 1 and five cases in group 2. There was significantly lower failure rate in group 1 than group 2 (p = 0.03). Neck-shaft angle at last follow-up was 134.8 degrees +/- 5.3 in group 1 and 131.3 degrees +/- 5.1 in group 2 (p = 0.01). The sliding length of lag screws were 5.6 degrees +/- 2.9 mm in group 1 and 8.3 degrees +/- 3.2 in group 2 (p = 0.03).

CONCLUSION

Preoperative use of MDCT provides useful information about the fracture pattern and the geometry of the proximal femur in unstable intertrochanteric fractures and helps surgical planning. The ratio of the LT to the GT is inversely correlated with fracture stability.

摘要

目的

探讨多层螺旋 CT(MDCT)在股骨近端三部分转子间骨折中的应用价值。

材料与方法

回顾性分析 26 例 Boyd-Griffin Ⅱ型转子间骨折患者的 MDCT 资料(A 组),并与 36 例无 MDCT 资料的同类型骨折患者(B 组)进行比较。小转子(LT)/大转子(GT)体积比>0.5 或 GT 体积占股骨近端总体积的比例<25%认为是不稳定骨折。所有患者均采用动力髋螺钉(DCS)固定,不稳定骨折加用大转子稳定钢板或股骨头骨水泥强化。比较两组患者的固定失败率和影像学结果。

结果

LT/GT 体积比为 0.33(范围,0.13~0.73)。LT 体积与 GT 体积呈负相关(p<0.001)。GT 体积与 LT/GT 比值或头颈(HN)/GT 比值呈显著正相关(p<0.001)。A 组 7 例被认为是不稳定骨折。A 组 1 例固定失败,B 组 5 例固定失败。A 组固定失败率明显低于 B 组(p=0.03)。末次随访时 A 组颈干角为 134.8°±5.3°,B 组为 131.3°±5.1°(p=0.01)。A 组拉力螺钉滑动长度为 5.6°±2.9mm,B 组为 8.3°±3.2mm(p=0.03)。

结论

术前 MDCT 可提供不稳定转子间骨折的骨折模式和股骨近端几何形态的有用信息,有助于手术规划。LT 与 GT 的比值与骨折稳定性呈负相关。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验