Department of Radiology, Weill Cornell Imaging at New York Presbyterian, New York, New York 10022, USA.
J Magn Reson Imaging. 2010 May;31(5):1176-84. doi: 10.1002/jmri.22136.
To evaluate the accuracy of magnetic resonance angiography (MRA) for preoperative mapping of rectus and gluteal muscle perforating arteries prior to autologous flap breast reconstruction.
Preoperative MRA on 25 consecutive patients undergoing perforator artery-based autologous breast reconstruction was performed at 1.5 T using 3D liver accelerate volume acquisition (LAVA) of abdominal or gluteal regions acquired during injection of 20 mL of gadobenate dimeglumine with bolus timing optimized using MR fluoroscopy or SmartPrep. Perforator artery size and coordinates relative to umbilicus or top of gluteal crease on 3D MRA were compared to findings at surgery. Reconstructed breast volume estimates from MRA were also compared to weights at harvesting.
In all, 132 perforator arteries were found at surgery to be located within 1 cm of the coordinates measured on MRA and were surgically verified to be suitable for flap perfusion. Surgery verified the arterial course and caliber through the rectus and gluteal muscles visualized on MRA in 48 of 49 arteries. Volume rendering of 3D MRA predicted a breast reconstruction volume with a mean difference of 47 g compared to measurements at harvesting.
MRA accurately maps rectus and gluteal muscle perforator arteries for preoperative planning of autologous flaps for breast reconstruction.
评估磁共振血管造影(MRA)在自体皮瓣乳房重建前对直肌和臀肌穿支动脉进行术前定位的准确性。
对 25 例连续接受穿支动脉自体乳房重建的患者在 1.5T 下进行术前 MRA 检查,使用腹部或臀部的 3D 肝脏加速容积采集(LAVA),在注射 20ml 钆贝葡胺后进行,使用 MR 透视或 SmartPrep 优化了团注时间。将 3D MRA 上测量的穿支动脉大小和相对于脐或臀皱襞顶点的坐标与手术结果进行比较。还将 MRA 上的重建乳房体积估计值与采集时的重量进行比较。
总共在手术中发现 132 条穿支动脉位于 MRA 测量坐标的 1cm 内,并且被手术证实适合皮瓣灌注。手术通过 MRA 上显示的穿过直肌和臀肌的动脉路径和口径在 49 条动脉中的 48 条中得到了验证。3D MRA 的容积渲染预测的乳房重建体积与采集时的测量值平均相差 47g。
MRA 可以准确地对直肌和臀肌穿支动脉进行术前定位,为自体皮瓣乳房重建的术前规划提供依据。