OBJECTIVE

When recording compound muscle action potentials, the active electrode is traditionally placed over the muscle and the reference over the corresponding tendon (belly-tendon recording). This placement assumes that the reference electrode is electrically inactive. We report on the influence of reference electrode placement on the compound muscle action potential recorded from the flexor digiti minimi brevis.

DESIGN

We recorded compound muscle action potentials from the flexor digiti minimi brevis using belly electrodes, tendon electrodes, and an electrode on the contralateral medial malleolus from 11 healthy subjects. We measured compound muscle action potential amplitudes and onset latencies.

RESULTS

Compound muscle action potentials recorded using electrodes on a tendon and the contralateral medial malleolus had higher amplitudes and shorter onset latencies than the compound muscle action potentials recorded with the belly-tendon montage.

CONCLUSIONS

When recording compound muscle action potentials from flexor digiti minimi brevis, the influences of the tendon "reference" electrode on latency and amplitude are large. Electrodiagnositicians should consider the influences of the reference electrode when assessing the lateral plantar nerve. This study may also inform us about the influence of proximally innervated muscles on the compound muscle action potential recorded in the limbs.

摘要

目的

在记录复合肌肉动作电位时,传统上将活动电极放置在肌肉上,参考电极放置在相应的肌腱上(腹部-肌腱记录)。这种放置假设参考电极没有电活性。我们报告了参考电极放置位置对从短屈趾肌记录的复合肌肉动作电位的影响。

设计

我们从 11 名健康受试者的短屈趾肌上使用腹部电极、肌腱电极和对侧内踝上的电极记录复合肌肉动作电位。我们测量了复合肌肉动作电位的幅度和起始潜伏期。

结果

与使用腹部-肌腱组合记录的复合肌肉动作电位相比,使用肌腱电极和对侧内踝上的电极记录的复合肌肉动作电位幅度更高,起始潜伏期更短。

结论

在从短屈趾肌记录复合肌肉动作电位时,肌腱“参考”电极对潜伏期和幅度的影响较大。电诊断医生在评估外侧足底神经时应考虑参考电极的影响。本研究还可以让我们了解近端支配肌肉对肢体记录的复合肌肉动作电位的影响。