Rowbottom S J, Simpson D L, Grubb D
Department of Anaesthetics, Royal Hospital for Sick Children, Edinburgh, Scotland, UK.
Anaesthesia. 1991 Jun;46(6):489-91. doi: 10.1111/j.1365-2044.1991.tb11693.x.
Clinical and fibreoptic assessment of the positioning of the laryngeal mask airway was performed in 100 children. Clinical observation indicated a patent airway in 98% and severe airway obstruction in 2% of cases. Perfect positioning, as judged by fibreoptic laryngoscopy, was found in 49% and the epiglottis was within the mask in 49%. Fibreoptic evidence of partial airway obstruction in 17% was not detected clinically.