Abstract

OBJECTIVE

Pseudoaneurysms are characterized by extravascular circulation and therefore may lead to an activation of the coagulation cascade. We investigated d-dimer levels in patients with and without postcatheterization femoral pseudoaneurysms and hypothesized that d-dimer levels correlate with the presence of pseudoaneurysms at the vascular access site.

METHODS

Patients with clinical suspected groin pseudoaneurysms after transluminal procedures were eligible. We compared prospectively-collected laboratory values of quantitative d-dimer testing in patients with and without pseudoaneurysms as assessed by color-coded duplex sonography. Furthermore, we measured the peak systolic velocity at the arterial fistula of each pseudoaneurysm.

RESULTS

In 48 (40%) of 120 consecutive patients, a pseudoaneurysm was found. The level of d-dimer values was significantly higher in patients with postcatheterization femoral pseudoaneurysms compared with controls (1.9 microg/mL [interquartile range (IQR), 1.34-2.78 microg/mL] vs 0.8 microg/mL [IQR, 0.53-1.14 microg/mL]; P < .001). Values of d-dimer below 0.67 microg/mL have been calculated with a sensitivity of 94% (87%-100%), a specificity of 38% (27%-50%), a positive predictive value of 50% (40%-60%), a negative predictive value of 90% (82%-99%), and a likelihood ratio of 1.52 (1.25-1.85) with regard to the presence of pseudoaneurysms. We also found a significant correlation of the peak systolic velocity at the arterial fistula and increasing d-dimer levels (r = 0.98, P < .0001).

CONCLUSION

We found a significantly higher level of d-dimer values in patients with femoral pseudoaneurysms at the vascular access site. Therefore, d-dimer levels could be a potential serological marker in the diagnosis of pseudoaneurysms. A confirmation is warranted in a larger patient sample.

摘要

目的

假性动脉瘤的特征是血管外循环,因此可能导致凝血级联反应的激活。我们研究了有和无经导管股假性动脉瘤患者的 D-二聚体水平,并假设 D-二聚体水平与血管入路部位假性动脉瘤的存在相关。

方法

经腔内手术后临床怀疑有腹股沟假性动脉瘤的患者符合条件。我们前瞻性比较了彩色双功能超声评估有和无假性动脉瘤患者的定量 D-二聚体检测的实验室值。此外,我们测量了每个假性动脉瘤动脉瘘口的收缩期峰值速度。

结果

在 120 例连续患者中,48 例(40%)发现假性动脉瘤。与对照组相比,经导管股假性动脉瘤患者的 D-二聚体值明显更高(1.9μg/ml[四分位距(IQR),1.34-2.78μg/ml]比 0.8μg/ml[IQR,0.53-1.14μg/ml];P<0.001)。计算出 D-二聚体值低于 0.67μg/ml 具有 94%(87%-100%)的灵敏度、38%(27%-50%)的特异性、50%(40%-60%)的阳性预测值、90%(82%-99%)的阴性预测值和 1.52(1.25-1.85)的似然比,与假性动脉瘤的存在相关。我们还发现动脉瘘口收缩期峰值速度与 D-二聚体水平升高呈显著相关(r=0.98,P<0.0001)。

结论

我们发现血管入路部位股假性动脉瘤患者的 D-二聚体值明显升高。因此,D-二聚体水平可能是假性动脉瘤诊断的潜在血清学标志物。需要在更大的患者样本中进行确认。