Suppr超能文献

AUDIT 完整版真的有必要吗?其简版的效度和内部结构研究。

Is the full version of the AUDIT really necessary? Study of the validity and internal construct of its abbreviated versions.

机构信息

Department of Neurosciences and Behavior, Ribeirão Preto Medical School, University of São Paulo, Ribeirão Preto, São Paulo, Brazil.

出版信息

Alcohol Clin Exp Res. 2010 Aug;34(8):1417-24. doi: 10.1111/j.1530-0277.2010.01225.x. Epub 2010 May 17.

Abstract

BACKGROUND

This study was aimed at assessing the psychometric qualities of the abbreviated versions of the Alcohol Use Disorders Identification Test (AUDIT-3, AUDIT-4, AUDIT-C, AUDIT-PC, AUDIT-QF, FAST, and Five-Shot) and at comparing them to the 10-item AUDIT and the CAGE in 2 samples of Brazilian adults.

METHODS

The validity and internal consistency of the scales were assessed in a sample of 530 subjects attended at an emergency department and at a Psychosocial Care Center for Alcohol and Drugs. The Structured Clinical Interview for DSM-IV was used as the diagnostic comparative measure for the predictive validity assessment. The concurrent validity between the scales was analyzed by means of Pearson's correlation coefficient.

RESULTS

The assessment of the predictive validity of the abbreviated versions showed high sensitivity (of 0.78 to 0.96) and specificity (of 0.74 to 0.94) indices, with areas under the curve as elevated as those of the AUDIT (0.89 and 0.92 to screen for abuse and 0.93 and 0.95 in the screening of dependence). The CAGE presented lower indices: 0.81 for abuse and 0.87 for dependence. The analysis of the internal consistency of the AUDIT and its versions exhibited Cronbach's alpha coefficients between 0.83 and 0.94, while the coefficient for the CAGE was 0.78. Significant correlations were found between the 10-item AUDIT and its versions, ranging from 0.91 to 0.99. Again, the results for the CAGE were satisfactory (0.77), although inferior to the other instruments.

CONCLUSIONS

The results obtained in this study confirm the validity of the abbreviated versions of the AUDIT for the screening of alcohol use disorders and show that their psychometric properties are as satisfactory as those of the 10-item AUDIT and the CAGE.

摘要

背景

本研究旨在评估酒精使用障碍识别测试(AUDIT-3、AUDIT-4、AUDIT-C、AUDIT-PC、AUDIT-QF、FAST 和 Five-Shot)缩写版本的心理测量特性,并在两个巴西成年人样本中对其与 10 项 AUDIT 和 CAGE 进行比较。

方法

在急诊科和酒精和药物心理社会护理中心就诊的 530 名受试者样本中评估了这些量表的效度和内部一致性。使用 DSM-IV 结构化临床访谈作为预测效度评估的诊断比较测量。通过皮尔逊相关系数分析了量表之间的同时效度。

结果

对缩写版本的预测效度评估显示,灵敏度(0.78 至 0.96)和特异性(0.74 至 0.94)指数较高,曲线下面积与 AUDIT 相当(分别为 0.89 和 0.92 用于筛查滥用,0.93 和 0.95 用于筛查依赖)。CAGE 的指数较低:滥用为 0.81,依赖为 0.87。对 AUDIT 及其版本的内部一致性进行分析,发现 Cronbach's alpha 系数在 0.83 至 0.94 之间,而 CAGE 的系数为 0.78。在 10 项 AUDIT 及其版本之间发现了显著的相关性,范围从 0.91 到 0.99。同样,CAGE 的结果也令人满意(0.77),尽管不如其他工具。

结论

本研究结果证实了 AUDIT 缩写版本用于筛查酒精使用障碍的有效性,并表明其心理测量特性与 10 项 AUDIT 和 CAGE 一样令人满意。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验