Suppr超能文献

三维能量多普勒超声获得的胎盘容积和血管指数的可重复性。

Reproducibility of placental volume and vasculature indices obtained by 3-dimensional power Doppler sonography.

机构信息

Division of Maternal-Fetal Medicine and Ultrasound, Department of Obstetrics and Gynecology, Washington University Medical Center, St Louis, MO 63110, USA.

出版信息

J Ultrasound Med. 2010 Jun;29(6):911-6. doi: 10.7863/jum.2010.29.6.911.

Abstract

OBJECTIVE

The purpose of this study was to evaluate the reproducibility of 3-dimensional (3D) power Doppler assessment of placental volumes and vascularization before adopting these in routine evaluation of normal and complicated pregnancies.

METHODS

A prospective study was performed on 30 normal singleton pregnancies from 11 to 14 weeks. To evaluate placental vascularization, 3D power Doppler sonography was applied to obtain a placental volume, and the volume acquired was analyzed using virtual organ computer-aided analysis. Two consecutive measurements were taken from each patient by two observers blinded to each other's and the individual's previous measurement. This yielded a total of 60 data set pairs. The placental volume, vascularization index, flow index, and vascularization-flow index (VFI) were calculated. Normal distribution of the data was confirmed with the Kolmogorov-Smirnov test. Intraobserver and interobserver correlations were evaluated. Bland-Altman plots and statistics were used to compare the 95% limits of agreement between measurements.

RESULTS

All 3D power Doppler placental volumes and vascular indices showed intraobserver correlations of 0.80 or higher. Similar excellent interobserver correlations were seen for all indices with the exception of the VFI, which showed a lower but acceptable correlation. The Bland-Altman analyses indicated good reproducibility of the evaluated placental indices.

CONCLUSIONS

Our findings provide validation of the technique, showing good reproducibility of the 3D power Doppler parameters when applied to studies of the placental volume and vascular tree.

摘要

目的

本研究旨在评估三维(3D)能量多普勒评估胎盘体积和血管化在常规评估正常和复杂妊娠中的可重复性。

方法

对 30 例 11-14 周的正常单胎妊娠进行前瞻性研究。为了评估胎盘血管化,应用 3D 能量多普勒超声获得胎盘体积,并使用虚拟器官计算机辅助分析(VOCAL)对所获得的体积进行分析。由两位观察者对每位患者进行两次连续测量,两位观察者彼此以及个体的前一次测量均不知情。总共获得了 60 对数据集。计算胎盘体积、血管化指数、血流指数和血管化-血流指数(VFI)。使用 Kolmogorov-Smirnov 检验确认数据的正态分布。评估观察者内和观察者间的相关性。Bland-Altman 图和统计学用于比较测量之间的 95%一致性界限。

结果

所有 3D 能量多普勒胎盘体积和血管指数的观察者内相关性均为 0.80 或更高。除 VFI 外,所有指数的观察者间相关性也相似,均为较高但可接受的相关性。Bland-Altman 分析表明评估的胎盘指数具有良好的可重复性。

结论

我们的研究结果为该技术提供了验证,表明 3D 能量多普勒参数在胎盘体积和血管树研究中的应用具有良好的可重复性。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验