非骨水泥型陶瓷对陶瓷全髋关节置换术中髋臼螺钉头部导致的陶瓷髋臼衬垫骨折

Acetabular screw head-induced ceramic acetabular liner fracture in cementless ceramic-on-ceramic total hip arthroplasty.

作者信息

Lee Su Chan, Jung Kwang Am, Nam Chang Hyun, Kim Tea Ho, Ahn Nong Kyoum, Hwang Seung Hyun

机构信息

Department of Orthopedic Surgery, Himchan Hospital, Seoul, South Korea.

出版信息

Orthopedics. 2010 May 12;33(5). doi: 10.3928/01477447-20100329-30.

Abstract

Ceramic liner fractures are rare after ceramic-on-ceramic THA. This article describes a case of an early ceramic liner fracture caused by impingement with a tilted acetabular screw head 2 months after cementless ceramic-on-ceramic THA. A 59-year-old man underwent primary THA for avascular necrosis of his right femoral head. The implant used was an Osteonics Secur-Fit HA ceramic-on-ceramic bearing system. The metal shell was fixed with 1 cancellous bone screw. During the index procedure, the acetabular screw seemed tilted in the metal shell hole, but the liner was fully seated in the metal shell without difficulty. However, 2 months later he re-presented due to pain and crepitation in the right hip. Radiographs showed that the ceramic acetabular insert had fractured. At revision, ceramic insert had fractured into large and numerous comminuted fragments, and the acetabular screw head was slightly tilted and protruded over the inner surface of the metal shell, which had worn eccentrically. The ceramic inner head and metal shell were visibly intact. Because the metal shell-bone fixation was firm, a new identical design ceramic liner and head were fitted, and no adverse event has occurred since. This case suggests that a complete check of the inside of the shell should be made when using an acetabular screw and ceramic liner. In particular, the screw head must not be tilted or left proud of the inside surface of the shell. Correct acetabular screw direction and seating are essential to avoid detrimental clinical consequences.

摘要

在陶瓷对陶瓷全髋关节置换术后,陶瓷内衬骨折较为罕见。本文描述了一例非骨水泥型陶瓷对陶瓷全髋关节置换术后2个月,因髋臼螺钉头部倾斜撞击导致早期陶瓷内衬骨折的病例。一名59岁男性因右股骨头缺血性坏死接受初次全髋关节置换术。所使用的植入物是Osteonics Secur-Fit HA陶瓷对陶瓷轴承系统。金属杯用1枚松质骨螺钉固定。在初次手术过程中,髋臼螺钉在金属杯孔内似乎有倾斜,但内衬在金属杯内顺利完全就位。然而,2个月后他因右髋疼痛和摩擦音再次就诊。X线片显示陶瓷髋臼内衬已骨折。翻修时,陶瓷内衬已断裂成大量粉碎性碎片,髋臼螺钉头部略有倾斜并突出于金属杯内表面,金属杯内表面已出现偏心磨损。陶瓷内股骨头和金属杯明显完好无损。由于金属杯与骨的固定牢固,安装了一个新的相同设计的陶瓷内衬和股骨头,此后未发生不良事件。该病例表明,在使用髋臼螺钉和陶瓷内衬时,应全面检查杯内部。特别是,螺钉头部不得倾斜或突出于杯内表面。正确的髋臼螺钉方向和就位对于避免不良临床后果至关重要。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验