全膝关节置换术后患者在不同速度行走时的膝关节动力学。

Knee kinetics during walking at different speeds in people who have undergone total knee replacement.

机构信息

School of Physiotherapy, La Trobe University, Melbourne, Victoria 3086, Australia.

出版信息

Gait Posture. 2010 Jun;32(2):205-10. doi: 10.1016/j.gaitpost.2010.04.009. Epub 2010 May 26.

Abstract

Previous research suggests that most people who have undergone total knee replacement (TKR) walk with a sagittal knee moment profile and peak knee moments that are different from normal. However, most previous research has consisted of small samples of patients with prostheses that are no longer in use. The aim of this study was to compare the peak knee moments and patterns of the moment waveforms of walking at different speeds between a large cohort of TKR patients with the Genesis-II PS prosthesis (Smith and Nephew, Memphis, USA) and matched control participants. Forty patients 12months following TKR and 40 control participants were assessed during walking at self-selected comfortable and fast speeds using motion analysis. Individual sagittal plane knee moment graphs were assessed for the presence of a biphasic pattern. Peak sagittal and coronal plane knee moments were compared between groups using a univariate ANOVA with walking speed as a covariate. A biphasic moment pattern was present in 87% and 92% of TKR patients when walking at comfortable and fast speeds, respectively. The knee flexor (p<0.001 at both speeds), extensor (p=0.004 at comfortable speed and p<0.001 at fast speed) and adductor (p<0.001 at both speeds) moments were reduced in the TKR patients. The high proportion of TKR patients with biphasic moment patterns was unexpected, but suggests that modern prostheses can result in more normal outcomes. Nonetheless, the peak knee moments of patients were reduced compared to controls. Although these reductions may be beneficial to the survival of the prosthesis, these abnormalities may also indicate suboptimal functional outcome from TKR.

摘要

先前的研究表明,大多数接受全膝关节置换术(TKR)的患者在矢状面膝关节力矩曲线和峰值膝关节力矩方面与正常人不同。然而,大多数先前的研究都是基于使用不再使用的假体的小样本患者进行的。本研究的目的是比较大量使用 Genesis-II PS 假体(美国史赛克公司)的 TKR 患者和匹配的对照组在不同速度下行走时的峰值膝关节力矩和力矩波形模式。40 名 TKR 术后 12 个月的患者和 40 名对照组参与者在使用运动分析以自身选择的舒适和快速速度行走时进行评估。对个体矢状面膝关节力矩曲线进行双相模式的评估。使用单变量方差分析,以行走速度为协变量,比较组间的峰值矢状面和冠状面膝关节力矩。当以舒适和快速速度行走时,分别有 87%和 92%的 TKR 患者出现双相力矩模式。TKR 患者的膝关节屈肌(在两种速度下均为 p<0.001)、伸肌(在舒适速度下为 p=0.004,在快速速度下为 p<0.001)和内收肌(在两种速度下均为 p<0.001)力矩减小。TKR 患者中出现双相力矩模式的比例很高,这出乎意料,但表明现代假体可以产生更正常的结果。尽管与对照组相比,患者的峰值膝关节力矩减小,但这些减少可能对假体的存活有益,但这些异常也可能表明 TKR 的功能结果不理想。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验