• 文献检索
  • 文档翻译
  • 深度研究
  • 学术资讯
  • Suppr Zotero 插件Zotero 插件
  • 邀请有礼
  • 套餐&价格
  • 历史记录
应用&插件
Suppr Zotero 插件Zotero 插件浏览器插件Mac 客户端Windows 客户端微信小程序
定价
高级版会员购买积分包购买API积分包
服务
文献检索文档翻译深度研究API 文档MCP 服务
关于我们
关于 Suppr公司介绍联系我们用户协议隐私条款
关注我们

Suppr 超能文献

核心技术专利:CN118964589B侵权必究
粤ICP备2023148730 号-1Suppr @ 2026

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验

[Influence of cardiac pacing on graft flow following aortocoronary bypass surgery--comparison of ventricular and atrial pacing].

作者信息

Yoshida H

机构信息

Department of Cardiac Surgery, Kawasaki Medical School, Kurashiki, Japan.

出版信息

Nihon Kyobu Geka Gakkai Zasshi. 1991 Mar;39(3):315-21.

PMID:2051089
Abstract

To evaluate the influence of cardiac pacing on hemodynamics and graft flow dynamics following aortocoronary bypass surgery, we measured vein graft flow, systolic and diastolic graft flow volume along with blood pressure and cardiac output during atrial and ventricular pacing in 20 patients, 26 grafts. During ventricular pacing, systolic blood pressure showed a significant decline of 17% at the minimum pacing rates (101 +/- 9/min), 17% and 21% at the pacing rates of 120 and 140, respectively (p less than 0.01) in comparison with the original heart rates (96 +/- 8/min). The cardiac output also decreased significantly (p less than 0.01) during ventricular pacing. Graft flow at the original heart rates was 86 +/- 22 ml/min and the graft flow at the minimum pacing rates, at the pacing rates of 120 and 140 decreased to 73 +/- 20, 75 +/- 21, 74 +/- 23 ml/min (P less than 0.01), respectively. These reduction in the graft flow were caused by a decrease in diastolic graft flow (p less than 0.01). In the patients with a history of myocardial infarction, ventricular pacing brought about much more decrease in blood pressure, cardiac output and graft flow volume than those in patients without myocardial infarction (p less than 0.01). During atrial pacing, no significant change was observed in blood pressure and cardiac output. The graft flow was 86 +/- 21 ml/min at the original heart rates and it increased to 93 +/- 24 at the pacing rates of 120 and 95 +/- 26 ml/min at the pacing rates of 140 (p less than 0.01). These increase in graft flow during atrial pacing were attributable to an increase in diastolic graft flow (p less than 0.05). These findings suggest that the atrial pacing following aortocoronary bypass surgery brings about the beneficial effects on coronary perfusion compared with ventricular pacing.

摘要

相似文献

1
[Influence of cardiac pacing on graft flow following aortocoronary bypass surgery--comparison of ventricular and atrial pacing].
Nihon Kyobu Geka Gakkai Zasshi. 1991 Mar;39(3):315-21.
2
Cardiac pacing induced flow responses in internal thoracic artery and saphenous vein coronary artery bypass grafts.
ASAIO J. 1995 Apr-Jun;41(2):198-201.
3
[Assessment of left internal thoracic artery grafts by atrial pacing].[通过心房起搏评估左胸廓内动脉移植物]
Kyobu Geka. 2003 Jun;56(6):455-8.
4
Temporary epicardial ventricular stimulation in patients with atrial fibrillation: acute effects of ventricular pacing site on bypass graft flows.心房颤动患者的临时心外膜心室刺激:心室起搏部位对旁路移植血管血流的急性影响
J Card Surg. 2009 Jul-Aug;24(4):424-8. doi: 10.1111/j.1540-8191.2008.00786.x.
5
Regional myocardial dimensions following coronary artery bypass grafting in patients. Relationship of functional deterioration to graft occlusion.
J Thorac Cardiovasc Surg. 1979 Jan;77(1):13-23.
6
[Effects of nitroglycerin on the graft flow during aortocoronary bypass surgery].
Kokyu To Junkan. 1989 Aug;37(8):885-90.
7
[Hemodynamic consequences of suddenly abolished atrial contraction].[心房收缩突然停止的血流动力学后果]
Z Kardiol. 1982 Dec;71(12):824-9.
8
Influence of atrioventricular synchrony on hemodynamics in patients with normal and low ejection fractions following open heart surgery.
Am Surg. 1986 Feb;52(2):93-6.
9
The effect of the site of placement of temporary epicardial pacemakers on ventricular function in patients undergoing cardiac surgery.心脏手术患者临时心外膜起搏器放置部位对心室功能的影响。
Circulation. 1984 Sep;70(3 Pt 2):I118-23.
10
[Effect of aortocoronary bypass surgery on left ventricular function and coronary sinus blood flow in patients with severe left ventricular dysfunction].
Nihon Geka Gakkai Zasshi. 1985 Dec;86(12):1646-53.