Suppr超能文献

血管内超声对退化性主动脉冠状动脉大隐静脉移植血管的虚拟组织学研究

Virtual histology by intravascular ultrasound study on degenerative aortocoronary saphenous vein grafts.

作者信息

Jim Man-Hong, Hau William Kong-to, Ko Ryan Lap-Yan, Siu Chung-Wah, Ho Hee-Hwa, Yiu Kai-Hang, Lau Chu-Pak, Chow Wing-Hing

机构信息

Cardiac Medical Unit, Grantham Hospital, 125 Wong Chuk Hang Road, Hong Kong, China.

出版信息

Heart Vessels. 2010 May;25(3):175-81. doi: 10.1007/s00380-009-1185-7. Epub 2010 May 29.

Abstract

Data of virtual histology (VH) acquired by intravascular ultrasound (IVUS) on saphenous vein graft (SVG) lesions is lacking. This study sought to report the VH IVUS findings in degenerative aortocoronary SVG lesions and correlate various types of plaque compositions (fibrous, fibro-fatty, dense calcium, and necrotic core) with different clinical and lesion characteristics. Virtual histology IVUS was performed on SVG in 38 symptomatic patients with a history of coronary artery bypass grafting, who underwent percutaneous coronary intervention on either native vessels or SVG. Measurements were made at the image slice with the smallest lumen. A total of 54 SVG lesions were analyzed; the mean graft age was 13.7 +/- 4.0 years. The mean vessel size was 5.0 +/- 1.0 mm; plaque area was 13.4 +/- 7.3 mm(2), and plaque burden was 63.0% +/- 15.0%. Fibrous tissue represented the major plaque component (62.1% +/- 17.1%). Lesions with a plaque burden of >or=70% were associated with positive remodeling, larger vessel size, higher percentage of fibro-fatty tissue, but lower percentage of dense calcium. Plaque burden was found to be positively correlated with remodeling index (r = 0.37, P = 0.01) and % fibro-fatty tissue (r = 0.49, P < 0.001) but negatively correlated with % dense calcium (r= -0.31, P = 0.03). The severity of SVG atherosclerosis paralleled with a proportional increase in fibro-fatty tissue. Unstable plaques in SVG were associated with positive remodeling, lipid-rich atheroma, and less calcium deposition, similar to the VH IVUS findings in native coronary arteries.

摘要

血管内超声(IVUS)获取的关于大隐静脉桥血管(SVG)病变的虚拟组织学(VH)数据尚缺。本研究旨在报告退行性主动脉冠状动脉SVG病变的VH-IVUS结果,并将各种类型的斑块成分(纤维性、纤维脂肪性、致密钙化和坏死核心)与不同的临床及病变特征相关联。对38例有冠状动脉旁路移植术病史且有症状的患者的SVG进行了VH-IVUS检查,这些患者接受了对自身血管或SVG的经皮冠状动脉介入治疗。在最小管腔的图像切片处进行测量。共分析了54处SVG病变;移植血管的平均年龄为13.7±4.0年。平均血管大小为5.0±1.0mm;斑块面积为13.4±7.3mm²,斑块负荷为63.0%±15.0%。纤维组织是主要的斑块成分(62.1%±17.1%)。斑块负荷≥70%的病变与阳性重构、较大的血管大小、较高比例的纤维脂肪组织相关,但致密钙化的比例较低。发现斑块负荷与重构指数呈正相关(r = 0.37,P = 0.01)以及与纤维脂肪组织百分比呈正相关(r = 0.49,P < 0.001),但与致密钙化百分比呈负相关(r = -0.31,P = 0.03)。SVG动脉粥样硬化的严重程度与纤维脂肪组织成比例增加平行。SVG中的不稳定斑块与阳性重构、富含脂质的粥样斑块以及较少的钙沉积相关,这与天然冠状动脉的VH-IVUS结果相似。

文献AI研究员

20分钟写一篇综述,助力文献阅读效率提升50倍。

立即体验

用中文搜PubMed

大模型驱动的PubMed中文搜索引擎

马上搜索

文档翻译

学术文献翻译模型,支持多种主流文档格式。

立即体验