OBJECTIVE

A method for fitting multichannel compression hearing aids with an extended high-frequency response, called CAMEQ2-HF, was described by . This study describes an evaluation of the method, using a 16-channel behind the ear hearing aid incorporating slow-acting compression and providing gain for frequencies up to 7500 Hz.

DESIGN

Eleven participants with mild to moderate cochlear hearing loss were fitted bilaterally using the gains prescribed by CAMEQ2-HF. The fittings were checked using real-ear measurements with swept sinusoidal signals, and adjustments were made so that the target gains at the center frequency of each channel were achieved with a typical tolerance of +/-3 dB for an input level of 65 dB and with a typical tolerance of +/-5 dB for levels of 50 and 80 dB SPL. Participants were asked to wear the hearing aids as much as possible in their everyday lives and to fill in questionnaires and a structured diary about their experience of loudness and their listening problems in everyday life, both for listening unaided and after a period of use of the aids.

RESULTS

Scores obtained using the Profile of Aided Loudness (PAL) indicated that the hearing aids led to a clear increase in loudness (relative to unaided listening) for weak sounds and to smaller increases in loudness for sounds of medium and high intensity. For aided listening, strong sounds were typically rated as "loud, but OK." Satisfaction ratings for loudness obtained using the PAL showed only small differences between unaided and aided listening. Responses obtained via the structured diary (for aided listening only) indicated that target speech was usually judged as "loud enough" in a variety of situations. Clarity judgments ranged from "reasonably clear" to "OK" for most situations, but fell to "not very clear" for a noisy group situation. The loudness of background sounds was mostly judged as "OK," except for the noisy group situation in which the background was judged "bit loud." Results from the Abbreviated Profile of Hearing-Aid Benefit questionnaire indicated fewer problems with "ease of communication," "reverberation," and "background noise" for aided than for unaided listening, but more problems with "aversiveness." Nine of 11 ratings of overall sound quality fell in the categories "satisfied" or "very satisfied."

CONCLUSIONS

The CAMEQ2-HF fitting method generally led to satisfactory loudness and sound quality in everyday life for people with mild to moderate hearing loss.

摘要

目的

通过描述 ,介绍了一种为具有扩展高频响应的多通道压缩助听器进行适配的方法,称为 CAMEQ2-HF。本研究描述了该方法的评估,使用了一种 16 通道耳后助听器,该助听器采用慢动作压缩,并提供高达 7500 Hz 的频率增益。

设计

11 名轻度至中度耳蜗听力损失的参与者使用 CAMEQ2-HF 规定的增益进行双侧适配。使用扫频正弦信号进行真耳测量检查适配情况,并进行调整,以使每个通道中心频率的目标增益在 65 dB 的典型输入水平下达到 +/-3 dB 的典型容差,在 50 和 80 dB SPL 的典型容差下达到 +/-5 dB 的典型容差。参与者被要求尽可能在日常生活中佩戴助听器,并填写问卷和结构化日记,记录他们在日常生活中使用和不使用助听器时的响度和听力问题体验。

结果

使用助听听阈评估问卷(PAL)获得的分数表明,助听器使弱声音的响度明显增加(与不使用助听器相比),而中高强度声音的响度增加较小。对于辅助听力,强声音通常被评为“响亮,但可以接受”。使用 PAL 获得的助听听阈满意度评分表明,使用和不使用助听器之间的差异很小。通过结构化日记获得的(仅适用于辅助听力)响应表明,在各种情况下,目标语音通常被判断为“足够响亮”。在大多数情况下,清晰度判断从“相当清晰”到“可以”,但在嘈杂的群体情况下下降到“不是很清晰”。背景声音的响度大多被判断为“可以”,除了嘈杂的群体情况下背景被判断为“有点响亮”。简短助听器受益问卷的结果表明,与不使用助听器相比,辅助听力时“交流的容易程度”、“混响”和“背景噪声”的问题较少,但“不舒适感”的问题较多。11 项总体音质评分中有 9 项落在“满意”或“非常满意”类别中。

结论

对于轻度至中度听力损失的人来说,CAMEQ2-HF 适配方法通常在日常生活中可获得令人满意的响度和音质。