Suppr超能文献

两种视觉评分系统在检测和评估乳牙窝沟龋活动状态中的临床性能。

Clinical performance of two visual scoring systems in detecting and assessing activity status of occlusal caries in primary teeth.

机构信息

Departmento de Ortodontia e Odontopediatria, Faculdade de Odontologia da Universidade de São Paulo, São Paulo, Brazil.

出版信息

Caries Res. 2010;44(3):300-8. doi: 10.1159/000315616. Epub 2010 Jun 8.

Abstract

This study aimed to compare the clinical performance of two sets of visual scoring criteria for detecting caries severity and assessing caries activity status in occlusal surfaces. Two visual scoring systems--the Nyvad criteria (NY) and the ICDAS-II including an adjunct system for lesion activity assessment (ICDAS-LAA)--were compared using 763 primary molars of 139 children aged 3-12 years. The examinations were performed by 2 calibrated examiners. A subsample (n = 50) was collected after extraction and histology with 0.1% red methyl dye was performed to validate lesion depth and activity. The reproducibility of the indices was calculated (kappa test) and ROC analysis was performed to assess their validity and related parameters were compared using McNemar's test. The association between the indices and with the histological examination was evaluated using Spearman's correlation coefficient (r(s)). Visual criteria showed excellent reproducibility both regarding severity (NY: 0.94; ICDAS-II: 0.91) and activity (NY: 0.90; LAA: 0.91). The NY and LAA showed good association in caries activity assessment (r(s) = 0.88; 95% CI = 0.86-0.89; p < 0.001). Nevertheless, considering only cavitated lesions, this association was not significant (p > 0.05). Concerning the severity, both indices presented similar validity parameters. At D2 threshold, the sensitivity was higher for NY (NY = 0.87; ICDAS = 0.61, p < 0.05). Regarding activity status, NY showed higher specificities and accuracies. In conclusion, NY and ICDAS-II criteria are comparable and present good reproducibility and validity to detect caries lesions and estimate their severities, but the LAA seems to overestimate the caries activity assessment of cavitated lesions compared to NY.

摘要

本研究旨在比较两种用于检测龋损严重程度和评估窝沟龋活动状态的视觉评分标准在临床性能方面的差异。本研究使用 763 颗 3-12 岁儿童的第一恒磨牙,比较了两种视觉评分系统——Nyvad 标准(NY)和包括病变活动性评估辅助系统的 ICDAS-II(ICDAS-LAA)。由 2 名经过校准的检查者进行检查。在提取后收集了一个子样本(n = 50),并用 0.1% 红色甲基染料进行组织学检查,以验证病变深度和活动性。计算了指数的可重复性(kappa 检验),并进行 ROC 分析以评估其有效性,并使用 McNemar 检验比较相关参数。使用 Spearman 相关系数(r(s))评估指数与组织学检查之间的相关性。视觉标准在严重程度(NY:0.94;ICDAS-II:0.91)和活动度(NY:0.90;LAA:0.91)方面均显示出极好的可重复性。NY 和 LAA 在龋病活动评估方面具有良好的相关性(r(s) = 0.88;95%CI = 0.86-0.89;p < 0.001)。然而,仅考虑龋损的腔隙性部分时,这种相关性并不显著(p > 0.05)。在严重程度方面,两个指数均具有相似的有效性参数。在 D2 阈值下,NY 的敏感性更高(NY = 0.87;ICDAS = 0.61,p < 0.05)。关于活动状态,NY 表现出更高的特异性和准确性。总之,NY 和 ICDAS-II 标准具有可比性,在检测龋病病变和评估其严重程度方面具有良好的可重复性和有效性,但与 NY 相比,LAA 似乎高估了龋病腔隙性病变的活动度评估。

文献检索

告别复杂PubMed语法,用中文像聊天一样搜索,搜遍4000万医学文献。AI智能推荐,让科研检索更轻松。

立即免费搜索

文件翻译

保留排版,准确专业,支持PDF/Word/PPT等文件格式,支持 12+语言互译。

免费翻译文档

深度研究

AI帮你快速写综述,25分钟生成高质量综述,智能提取关键信息,辅助科研写作。

立即免费体验