Suppr超能文献

3T 磁共振引导下使用专用大芯活检套件进行乳腺活检:可行性及初步结果。

MRI-guided breast biopsy at 3T using a dedicated large core biopsy set: feasibility and initial results.

机构信息

Department of Radiology, Radboud University Nijmegen Medical Centre, Geert Grooteplein-Zuid 10, 6525GA Nijmegen, The Netherlands.

出版信息

Eur J Radiol. 2011 Aug;79(2):257-61. doi: 10.1016/j.ejrad.2010.05.001. Epub 2010 Jun 11.

Abstract

OBJECTIVE

The increasing importance of breast MRI in the diagnostic processes concerning breast cancer yield often lesions that are visible on MRI only. To assess the nature of these lesions, pathologic analysis is necessary. Therefore, MR-guided biopsy should be available. Breast MRI at 3T has shown advantage over 1.5T. Unfortunately, current equipment for MR-guided biopsy is better suited for intervention at 1.5T due to the danger of heating titanium co-axial sleeves and large susceptibility artifacts. We evaluated a dedicated 3T breast biopsy set that uses plastic coaxial needles to overcome these problems.

MATERIALS AND METHODS

We performed MRI-guided breast biopsy in 23 women with 24 MRI-only visible breast lesions at 3T. Biopsy procedures were performed with plastic coaxial needles in a closed bore 3T clinical MR system on a dedicated phased array breast coil with a commercially available add-on stereotactic biopsy device.

RESULTS

Width of the needle artifact was 2mm in all 24 cases. Biopsy procedure was completed between 35 and 67 min. The procedure was judged moderately easy in 12 and normal in 10 cases. One procedure was judged difficult and there was one technical failure.

CONCLUSION

MRI-guided breast biopsy at 3T is a fast and accurate procedure. The plastic coaxial needles reduce the susceptibility artifact largely and do not increase the difficulty of the procedure. The diagnostic yield is at least equal to the diagnostic yield of the same procedure at 1.5T. Therefore, this technique can be safely used for lesions only visible at 3T MRI.

摘要

目的

乳腺磁共振成像(MRI)在乳腺癌诊断中的重要性日益增加,经常会发现仅在 MRI 上可见的病变。为了评估这些病变的性质,需要进行病理分析。因此,需要进行磁共振引导下活检。3T 的乳腺 MRI 优于 1.5T。不幸的是,由于钛同轴套管加热和大的磁化率伪影的危险,目前用于磁共振引导活检的设备更适合 1.5T 的介入。我们评估了一种专用的 3T 乳腺活检套件,该套件使用塑料同轴针来克服这些问题。

材料和方法

我们在 23 名女性中进行了 24 例仅在 MRI 上可见的乳腺病变的 3T 磁共振引导下活检。在 3T 临床磁共振系统的封闭孔中,使用塑料同轴针和带有市售附加立体定向活检设备的专用相控阵乳腺线圈进行活检程序。

结果

24 例中的所有病例的针伪影宽度均为 2mm。活检程序在 35 至 67 分钟之间完成。12 例被认为是中度容易,10 例是正常的。1 例被认为是困难的,有 1 例技术失败。

结论

3T 磁共振引导下乳腺活检是一种快速准确的程序。塑料同轴针大大减少了磁化率伪影,并没有增加程序的难度。诊断率至少与 1.5T 相同程序的诊断率相等。因此,该技术可安全用于仅在 3T MRI 上可见的病变。